摘要
本文提出了应用石英晶体谐振天平技术测量返油率的新方法。通过理论分析和试验研究,证明这种方法可以推广应用。返油率在10-3~10-4mg/cm2·min量级上进行了实际测量,取得了满意的效果。
AbstractIn this paper,we put forward a new method of applying the technology of quartz-crystal microbalance to the measurment of oil back-streaming of diffusion pump.With analysing the technology in theory and studying experiments,It is proved that it is extensively used.We measured theoil back-streaming of diffusion pump between 10-3 and 10-4 mg/cm2.min and obtained satisfyingresult.
出处
《真空》
CAS
北大核心
1995年第2期25-29,共5页
Vacuum