本文叙述了抽水蓄能电厂同步电机动态稳定性能的研究结果及电力系统稳定器在抽水蓄能电厂应用时应解决的特殊问题,并以单机无限大系统和24机系统为例给出了计算结果。
This Paper describes the dynamic Performance of the Pum--generator system. The results show that the system may ocuur negetive damping under both operations of generating and pumping. The specific characteristics of selecting the parameters of power system stabilizer (PSS) is also given.