期刊文献+

有抽水蓄能电站的联合电力系统优化调度模型和算法 被引量:16

Model and Approach of Optimal Operation for Hydrothermal Power System with Pumped-Storage Stations
下载PDF
导出
摘要 本文介绍了一组有抽水蓄能电厂的电力系统优化调度的模型和算法,包括机组的最优起停。用Lagrangian松弛法将问题分解为多个子系统,对协调级建议一种灵敏系数法代替常规的次梯度法、速度快适应性好;火电机组组合采用分解的方法,对抽水蓄能电厂的模型作了详细的描述,考虑了上、下游水库水位变化的影响。提出一种最大增益网的算法,可最优选择日抽水量。相应的模型和算法已成功地用于实际系统,并用于运行计划及效益分析的计算.证明了其合理性及有效性。 In this paper,the model and approach of optimal operation for power system with pumped-storage plants are presented,including unit commitment. A sensitivity coefficient coordination algorithm between two levels for Lagrangian relaxation method is proposed instead of conventional subgradient algorithm. The model of pumped-storage is described accurately considering level variations of upstream and downstream reservoirs. A maximum gain-newtwork algorithm is given for optimal choosing the volume of daily pumped water. The model and algorithm have been applied in an actual large-scale system,and proved to be efficient and practical.
机构地区 清华大学
出处 《中国电机工程学报》 EI CSCD 北大核心 1995年第4期274-280,共7页 Proceedings of the CSEE
关键词 抽水蓄能电站 电力系统 调度模型 pumped-storage plant large-scale system hydro-thermal power system operation planning economic dispatch
  • 相关文献

参考文献3

二级参考文献3

  • 1陈刚,1991年
  • 2左长春,中国电机工程学报,1991年,6期
  • 3陈雪青,清华大学学报,1987年,1期

共引文献13

同被引文献121

引证文献16

二级引证文献128