期刊文献+

睢宁二站泵房结构设计方案比选及抗震分析 被引量:1

Choice of Structural Design Scheme and Anti-seismic Analysis for Pump House Structure of Suining Pump Station Ⅱ
下载PDF
导出
摘要 针对睢宁二站分离式泵站特点,采用非线性有限元ADINA软件,建立了睢宁泵站的结构地基水体三维有限元动力分析模型,分析比较了正常抽水状态下两个设计方案泵房结构的动力特性,运用流固耦合及时程分析方法分析了泵房结构在8度(0.3g)地震时的动力响应,给出了推荐方案。研究结果可为工程设计施工提供参考依据。 Based on the property of separating Suining Pumping Station Ⅱ,three dimensional dynamic finite element analysis model of structure foundation water body is built by ADINA to compare and analyze the dynamic characteristics of pump house structure on two design schemes under the normal pumping condition.Fluid solid coupling and time-histories analysis methods are used to calculate the dynamic response of the pump house structure with acceleration of 0.3g.The results provide scientific reference for engineering design and construction.
出处 《水电能源科学》 北大核心 2010年第7期74-77,共4页 Water Resources and Power
  • 相关文献

参考文献3

二级参考文献9

共引文献6

同被引文献12

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;