期刊文献+

微波注入实验用高隔离度双工器的研究

Research on high-isolation diplexer used in microwave injection experiment
下载PDF
导出
摘要 微波注入实验要求微波注入电路和效应监测电路的接入不影响正常的电路器件工作状态,同时要求注入电路隔离度足够大。在此设计了一种高隔离度微波双工器0~800MHz和1.4~4.5GHz,两信号通道内插入损耗小于0.2dB;0~400MHz和1.5~4.5GHz两信号通道隔离度大于50dB。这种微带线型双工器结构紧凑、研制周期短、性能稳定已经在微波效应注入实验系统中获得良好的应用。 In the microwave injection experiment the insertion of the microwave injection circuit and the effect inspect circuit is required not to affect the work condition of the electrical devices.The injection circuit is required to have enough isolation.One microwave diplexer with high isolation was designed.Between 0~800 MHz and 1.4~4.5 GHz,the insertion loss of the microwave diplexer is less than 0.2 dB.The isolation between two channels is higher than 50 dB.The microwave diplexer owns the characteristics of compact structure,short developing cycle and steady performance.It works well in microwave effect injection experiment system.
出处 《现代电子技术》 2012年第4期205-207,210,共4页 Modern Electronics Technique
基金 武器装备预研基金资助课题(103.1.2E022050205)
关键词 高隔离度 双工器 注入实验 插入损耗 high isolation diplexer injection experiment insertion loss
  • 相关文献

参考文献10

二级参考文献37

  • 1杨洁,刘尚合,原青云,武占成.微电子器件方波EMP注入敏感端对的实验研究[J].军械工程学院学报,2004,16(6):1-3. 被引量:3
  • 2杨小牛 楼才义 徐建良 179-189.软件无线电原理及应用[M].北京:电子工业出版社,2001..
  • 3刘尚合,武占成,朱长清,等.静电放电与危害防护[M].北京:邮电大学出版社,2004.
  • 4王长河.电子元器件辐射效应及加固技术研究及展望.抗核加固,1997,(6):55-65.
  • 5IEC 61000-4-5,1995.Electromagnetic compatibility-Part 4-5:Testing and techniques-Surge immunity test[S].
  • 6CALOZ C, OKABE H, ITOH T. Transmission line ap- proach of left-handed (LH) materials [J]. IEEE Trans. on Antennas and Propagation, 2004, 52(5):1159-1166.
  • 7CALOZ C, ITOH T. Electromagnetic metamaterials: transmission line theory and microwave applications [M]. New York: Wiley, 2004.
  • 8LAI A, CALOZ C, ITOH T. Composite right/left-handed transmission line metamaterials [J]. IEEE Microwave Magazine, 2004, 5(3): 34-50.
  • 9OKABE H, CALOZ C, ITOH T. A compact enhanced bandwidth hybrid ring using an artificial lumped-element left-handed transmission-line section [J]. IEEE Trans. on Microw. Theory Tech., 2004, 52(3): 798-804.
  • 10HU X, ZHANG P. A novel dual-band balun based on the dual structure of composite right/left handed transmission line [C]// Intenational Symposium on Biophotonics, Nanophotonics and Metamaterials. Hangzhou, China: Zhejiang University, 2006: 529-532.