摘要
台山电厂一期国产机组中的汽动给水泵组台座第1次使用了弹性支承设计,并进行了振动实测。汽动给水泵组弹性支承台座的振动最大实测均方根振动速度为0.42mm/s,即工频下的最大振动线位移为1.09μm;工频激振响应的最大振动线位移为0.60μm。该振动水平都在安全的A区域内。振动实测表明:用国际标准转化的国家标准进行振动分析,比用《动力机器基础设计规范》GB50040的分析更符合实际。
This paper introduces the design and the measurement information of spring supported turbine driven boiler feed pump foundation deck at Taishan Power Plant, which is the first one to use spring foundation for whole domestic supplied machines. Measurement shows that the maximum RMS velocity is 0.42 mm/s, the equivlant displacement transferred from RMS velocity at rated speed is 1.09 μm, the maximum response displacement to rated speed excitation is 0.60μm. The vibration level at Taishan is excellent and in region A with any criteria. Measurement shows that analysis with those national codes transferred from ISO codes is better in accordance with practice than that with 〈 Code for design of dynamic machine foundation 〉 GB 50040.
出处
《电力建设》
2005年第8期41-44,共4页
Electric Power Construction
关键词
汽动给水泵组
弹性支承台座
振动测量
标准比较
turbine driving feed water pump
spring supported foundation deck
vibration measurement
criteria comparison