摘要
研究了5种测定拟合火道温度的不同方法。通过对蓄顶温度与跨越孔温度随结焦时间与换向时间变化规律的测定与比较,最终选定蓄顶温度与火道温度相关方程作为OCC系统中的拟合火道温度。
Introduces 5 measurements of analogue flue temperature and compares their advantage and disadvantage. The temperature changing principle of span bole and the regenecator-top in a change-over time and coking period is measured and compared. So the relation equation of the flue and regenerator-top temperature is used as simulative flue temperature in the Optimizing Cascade Control System for the heating og coke ovens.
出处
《山东冶金》
CAS
2005年第3期33-36,共4页
Shandong Metallurgy
关键词
焦炉
拟合火道温度
结焦时间
换向时间
蓄顶温度
coke oven
simulative flue temperature
coking period
change-over time
regenerator-top temperature