摘要 Recent progress of study on gas electron multiplier (GEM) has been described. Due to its fast time re-sponse and excellent position sensitivity, the GEM will find wide applications in particle physics, medicine and as-trophysics. These potential applications have been briefly introduced. Recent progress of study on gas electron multiplier (GEM) has been described. Due to its fast time response and excellent position sensitivity, the GEM will find wide applications in particle physics, medicine and astrophysics. These potential applications have been briefly introduced.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2005年第4期225-230,共6页 核技术(英文)
关键词 GEM 气体电子倍增器 检测器 MSGC 微波传输带 气体室 高能物理 Gas electron multiplier, High rate radiation detector, Particle tracking, Fast triggering
  • 相关文献

参考文献23

  • 1Sauli F, Meinschad T, Musa L, et al. Ann Rev Nucl Part Sci, 1999, 49:341.
  • 2Oed A. Nucl Instr Meth, 2001, A471:109.
  • 3Sauli F. Nucl Instr Meth, 1997, A386:531.
  • 4Altunbas M C, Dehmelt K, Kappler S, et al. Nucl Instr Meth, 2003, A515:249.
  • 5Sauli F, Meinschad T, Musa L, et al. IEEE Nuclear Science Symposium, Norfolk, 2002.
  • 6MAXWELL Commercial Finite Element Computation Package. Ansoft Co. Pittsburgh, PA, USA.
  • 7Bachmann S, Bressan A, Capeans M, et al. Nucl Instr Meth, 2002, A479:294.
  • 8Inuzuka M, Hamagaki H, Ozawa K, et al. Nucl Instr Meth,2004, A525:529.
  • 9Pitts W K, Martin M D, Belolipetskiy S, et al. Nucl Instr.Meth, 1999, A438:277.
  • 10Barbeau P S, Collar G I, Geissinger J D, et al. Nucl Instr Meth, 2003, A515:439.

同被引文献7

  • 1Sauli F.GEM:A new concept for electron amplification in gas detectors[J].Nuclear Instruments and Methods in Physics Research A,1997,386:531-534.
  • 2Bressan A,De Oliveira R,Gandi A,et al.Two-dimensional readout of GEM detectors[J].Nuclear Instruments and Methods in Physics Research A,1999,425:254-261.
  • 3Tsyganov E,Buzulutskov A,Antich P.Triple GEM structure for medical imaging[C]∥IEEE Nucl Sci Syrup Med Imaging Conf Norfolk,VA,United States:IEEE Press,2002,2:1163-1166.
  • 4Colas P,Colijn A P,Fornaini A,et al.The readout of a GEM or Micromegas-equipped TPC by means of the Medipix2 CMOS sensor as direct anode[J].Nuclear Instruments and Methods in Physics Research A,2004,535:506-510.
  • 5Black J K,Deines-Jones P,Ready S E,et al.x-ray polarimetry with an active-matrix pixel proportional counter[J].Nuclear Instruments and Methods in Physics Research A,2003,513:639-643.
  • 6ZHAO Wei,Rowlands J A.Digital radiology using self-scanned readout of amorphous selenium[J].SPIE Physics of Medical Imaging,1993,1896:114-120.
  • 7XU Weize,Friedman E G.Clock feedthrough in CMOS analog transmission gate switches[J].Analog Integrated Circuits and Signal Processing,2005,44:271-281.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部