摘要 介绍珠钢150 t DANIELI电炉的改造和优化.改造提高了氧气利用率,解决了氧枪、烧嘴和水冷板漏水以及沉降室高温剥落、坍塌等问题,提高了各项技术经济指标. The details of modifying and optimizing the 150t DANIELI-EAF at Zhujiang Steel Co. are summarized. As a result of the modification and optimization, the utilization efficiency of oxygen was enhanced, the problems associated with the water leakage in the oxygen lance, nozzle and water-cooling plate, as well as with the spalling and collapsing of the high-temperature sedimentation chamber were solved, and the technical and economical indexes increased.
出处 《南方金属》 CAS 2005年第5期33-36,共4页 Southern Metals
关键词 改造 优化 DANIEI电炉 modification optimization DANIELI-EAF