摘要 目的建立静压管桩施工终压力与单桩极限承载力之间的关系,指导辽沈地区静压管桩工程实践.方法通过对辽沈地区不同地质条件下大量静压管桩的载荷试验研究,依据Q^S曲线等试验成果给出单桩极限承载力,采用数理统计方法对终压力和单桩极限承载力的关系进行分析.结果建立了不同地质条件、不同桩长的静压管桩终压力与单桩极限承载力之间的关系,依据实验结果及辽沈地区两者关系的效应系数,提出在静压管桩的施工中应采用设计标高和终压力双重控制.结论由于地质条件的差异,静压管桩的承载特性明显不同,辽沈地区静压管桩的终压力和单桩极限承载力的关系与南方地区有很大的差别,工程实践表明:在辽沈地区静压管桩的施工中,施行设计标高与终压力双重控制是适合的. In order to establish the relationship between the construction final pressure of static pile and the ultimate carrying capacity of single pile, and to guide the static pressure pipe pile in engineering practice in Liao-Shen area, a number of data from the static load test in different geological condition of Liao-Shen area are analyzed, and the ultimate carrying capacity of single pile is confirmed according to the Q-S curve. The relationship is analyzed between the construction final pressure of static pile and the ultimate carrying capacity of single pile with mathematical statistics method. The different geology condition and different length. The effect relationship is established between the two with factor is given out for them according to the experiment result. Proposals should be adopted about double-standard controlling, design elevation and final pressure, in the construction of static pressure pile. Owing to the differences of the geology condition, the capacity property of the static pressure pipe piles is different obviously. The relationship between the two in Liao-Shen area has apparent discrepancy in the southern part. Engineering practice has proved that double standards controlling is suitable in static pressure pile construction in Liao-Shen area.
出处 《沈阳建筑大学学报(自然科学版)》 EI CAS 2005年第4期302-305,共4页 Journal of Shenyang Jianzhu University:Natural Science
基金 辽宁省地方规范项目 建设部科技项目(05-K1-9)
关键词 辽沈地区 静压管桩 静载荷试验 单桩极限承载力 终压力 效应系数 关系研究 管桩施工 地质条件 数理统计方法 Liao-Shen area, static pressure concretesingle pile, final pressure, effect factorpipe pile, static load test, ultimate carrying capacity of
  • 相关文献

参考文献10

二级参考文献12

  • 1-.JGJ 94-94建筑桩基技术规范[M].北京:中国建筑工业出版社,1995..
  • 2-.桩基工程手册[M].北京:中国建筑工业出版社,1995..
  • 3黎志中 张汉.试论静压预制桩的承载力.广东省土木建筑学会土力学与基础工程学术委员会1995年学术交流会《论文选编》[M].,1995..
  • 4.DBJ/T15-22-98.预应力混凝土管桩基础技术规程[S].,..
  • 5.JGJ94-94.建筑桩基技术规范[S].,..
  • 6冶金工业部建筑研究总院.地基处理技术⑶[M].北京:冶金工业出版社,1992..
  • 7朱建新 何清华.液压静力压桩机的研究开发现状及其发展趋势[J].预制混凝土桩,2004,1(2):19-19.
  • 8王仕方,梁志刚.预应力管桩在中国银行温岭市支行商住综合楼工程中的应用[A].史佩栋等.21世纪高层建筑基础工程[C].北京:中国建筑工业出版社,2000.429—432.
  • 9金舜.我国预应力混凝土管桩的发展现状和发展方向探讨[J].预制混凝土桩,2004,1(2):189-189.
  • 10黎志中.静压桩桩长,终压力,极限承载力关系研究[J].岩土工程师,1999,11(4):35-40. 被引量:11