基于1999年在北满特殊钢股份有限公司新50万吨钢生产线的供电方案研究过程中的分析和论证,结合该生产线投产运行后的监测情况,针对对干扰性负荷供电系统的分析和谐波、闪变及三相不平衡的计算,以及如何加强管理并采取补偿抑制措施,提出了干扰性负荷供电的建议。
Some suggestions for ensuring power supply feasibility to disturbing loads were presented in the paper, based on the analysis and argumentation of power supply scheme of a new half million tons steel production line built in 1999 for Beiman Special Steel Co. Ltd, combined with the supervision results after put into use, focused on the analysis of power supply system for disturbing loads and the calculation of harmonic, flicker and three - phase unbalance, and how to enhance management and take measures to compensation also as well.
出处
《黑龙江电力》
CAS
2005年第4期251-254,共4页
Heilongjiang Electric Power
关键词
干扰性负荷
供电
分析
电网
供电质量
disturbing load
power supply
analysis
power grid
power supply quality