阻抗型逆变器的一种非正常工作状态分析 被引量:29

An Abnormal Operating State Analysis of Z-Source Inverter
下载PDF
导出
摘要 深入分析了阻抗型逆变器的电路工作原理,详细阐述了一种可以导致阻抗型逆变器工作在非正常的状态下的原因和该状态发生的条件,提出了有效的解决方法并以实验验证。 Based on the operating principle of the Z-source inverter, an abnormal operating state of Z-source inverter is found and analyzed. An undesired drop of the dc link voltage before the inverter occurs in the interval of abnormal operating state, which would lower the ac output voltage quality. Through detailed analysis of the cause and the operating condition, the effective solution is proposed and the experiment results prove the validity of the theoretical analysis.
出处 《电工技术学报》 EI CSCD 北大核心 2005年第8期55-58,77,共5页 Transactions of China Electrotechnical Society
关键词 阻抗型 逆变器 非正常工作状态 Z-source, inverter, abnormal operating state
  • 相关文献

参考文献5

  • 1Peng F. Z-source inverter. IEEE Transactions on Industry Applications, 2003, 39(2): 504-510.
  • 2Peng F, Yuan X, Fang X, et al. Z-source inverter for adjustable speed drives. IEEE Power Electronics Letters, 2003, 1(2):33 -35.
  • 3Peng F. Z-Source Inverter for Motor Drives. Procee dings oflEEE PESC' 04, 2004:249-254.
  • 4Fang X, Qian Z, Gao Q, et al. Current mode Z-source inverter-fed ASD system. Proceedings of IEEE PESC'04, 2004 : 2805-2809.
  • 5Peng F, Shen M, Qian Z. Maximum boost control of the Z-source inverter. Proceedings of IEEE PESC' 04,2004. 255-260.