通过对300MW机组锅炉引风机变频调速状态下一些运行参数的分析,揭示了引风机变频运行的基本特点,对其它机组运行分析有一定借鉴意义,同时部分计算过程和结论对风机耦合器变速调节分析也适应。
Through analysis of operational parameters of induced draft fan for 300MW boiler, the basic characteristic of frequency variable operation is revealed, and it may be reference to other units. Some calculation results and procedure are also suitable for the operational analysis of speed adjusting of fan coupler.
出处
《风机技术》
2005年第4期40-42,共3页
Chinese Journal of Turbomachinery
关键词
引风机
变频
特点
分析
Induced draft fan Frequency convertor Characteristic Analysis