期刊文献+

基于聚合物碳黑混合物气敏微传感器的研究 被引量:2

Gas Microsensors Based on Polymer-Carbon Black Composites
下载PDF
导出
摘要 通过四种不同的聚合物敏感材料以及混合的碳黑修饰在梳状微电极上,可以得到这种新型的化学气敏电阻型微传感器,将这四种不同聚合物的微传感器分别对丙酮、乙醇、甲醇、甲苯四种有机类气体进行了测试,比较其电阻的相对变化率,利用其响应的主元分析可以将四种气体区分开,并且在一定范围内,电阻的相对变化率可呈一定的线性分布。 A novel chemical gas sensor based on polymer-carbon black composite was developed. The four different polymer-carbon black composite are employed as the sensing materials which are immobilized on the interdigitated microelectrode pair. The resistance changes of sensors to four organic gases (acetone, ethanol, toluene and methanol) have been examined. By principle component analysis of responses of micro-sensors, four kinds of the same concentration different gases can be easily discriminated. Furthermore the relationship between the resistance changes and gas concentration in a certain range can be approximated to a straight line.
出处 《传感技术学报》 CAS CSCD 北大核心 2005年第3期504-506,513,共4页 Chinese Journal of Sensors and Actuators
关键词 微传感器 聚合物碳黑混合物 气敏传感器 micro-sensors polymer-carbon black composite gas sensor
  • 相关文献

参考文献4

  • 1白韶红.新一代高分子(聚合物)传感器[J].电子仪器仪表用户,1996(5):5-7. 被引量:2
  • 2Severion E J. and Lewis N S. Relationships among Resonant Frequency Changes on a Coated Quartz Micro-balance, Thickness Changes, and Resistance Responses of Polymer-Carbon Black Composite Chemiresistors[J].Anal. Chem,2000,72:2008-2015.
  • 3Zee B F, Judy J W.Micromachined polymer-based chemical gas sensor array[J].Sensors and Actuators,2001, 72:120-128.
  • 4[美]李宏东姚天翔译 RichardO Duda PeterE Hart DavidG Stork著.模式分类[M].,2003.94-102.

共引文献1

同被引文献18

  • 1祝柏林,谢长生.ZnO气敏材料的研究进展[J].传感技术学报,2002,15(4):353-359. 被引量:11
  • 2李松,Martin Jaegle,Harald Boettner.金属氧化物气体传感器阵列的制备[J].传感技术学报,2005,18(1):36-38. 被引量:8
  • 3Frank Zee,Jack W Judy.Micromachined polymer-based chemical gas sensor array[J].Sensors and Actuators B,2001,72:120-128.
  • 4Doleman B J,Lonergan M C,Severin E J,et al.Quantitative Study of the Resolving power of Arrays of Carbon[J].Analytical Chemcal,1998,70:4177-4190.
  • 5Kim Y S,Ha S C,Yoo,Yang Y,et al.Portable electronic nose system based on the carbon black-polymer composite sensor array[J].Sensors and Actuators B,2005,108(1-2):285-291.
  • 6Liu Y,Zou X X,Dong S J.et al.Electrochemical characteristics of facile prepared carbon nanotubes-ionic liquid gel modified microelectrode and application in bioelectrochemistry[J].Electrochemistey Communication,2006,8(9):1429-1434.
  • 7Zhao Y F,Gao Y Q,Zhao D P,et al.Selective detection of dopamine in the presence of ascorbic acid and uric acid by a carbon nanotubes-ionic liquid gel modified electrode[J].Talanta,2005,66(1):51-57.
  • 8Lewandowski A,Galinski M.Carbon-ionic liquid double-layer capacitors[J].Jounal of physics and chemistry of solids,2004,65(2-3):281-286.
  • 9Huddleston J G,Visser A E,Reichert W M,et al.Characterization and comparison of hydrophilic and hydrophobic room temperature ionic liquids incorporating the imidazolium cation[J].Green Chemistry,2001,3(4):156-164.
  • 10Lonergan Mark C, Severin Erik J, et al. Array-Based Vapor Sensing Using Chemically SensitiveCarbon Black-Polymer Resistors[J]. Chem. Mater. 1996, 8: 2298-2312.