摘要 对已达到要求耦合比的熔锥型单模光纤耦合器,继续用低温火焰烧灼耦合区制成了用于测量建筑物应变的耦合型光纤应变传感器,并用环氧树脂将其粘贴在实际的钢筋混凝土梁上与传统电阻应变片同时进行应变测试,试验结果表明,这种传感器实际测量钢筋混凝土的拉、压应变与电测值的差别,当应变超过80με时都在10%以内,可以在工程实际中使用。 Making a novel coupling optical fiber strain sensor based on to heat continually the coupled zone of single-mode fused optical fiber coupler to the required coupling. Pasting the sensor and traditional resistive strain gauge on the reinforced concrete girder the strains were measured with the sensor and gauge at one time. The result shows that the difference of both compress and stretch strain between the data obtained from coupling optical fiber strain sensor and traditional resistive strain gauge is within about 10% when strain is greater than 80με. It is possible to he used inthe practical engineering.
出处 《传感技术学报》 CAS CSCD 北大核心 2005年第3期593-595,共3页 Chinese Journal of Sensors and Actuators
基金 天津市自然科学基金资助项目(013601711)
关键词 熔锥型光纤耦合器 应变 耦合比 fused optical fiber coupler strain coupling ratio
  • 相关文献

参考文献6

  • 1Sayeh M R. Multiplexed fiber-optical strain sensor system[C].In:SPIE,1999,3670:385-390.
  • 2LIN Xuehuang.Optical passive device[M].Post & Telecom Press,1998,112~116.
  • 3Asundi A. Health monitoring of structures using fiber sensors[C].In:SPIE,1998,3666:506-513.
  • 4Schulz W. Traffic monitoring/control and road condition monitoring using fiber optic based systems[J].SPIE,1999,3671:109-117.
  • 5Kabashima S. Damage detection of satellite structures by optical fiber with small diameter[C].In:SPIE,2000,3985:343-351.
  • 6李川,张以谟,刘铁根,李欣,张大煦.Y型熔锥光纤耦合器的应变响应[J].光子学报,2001,30(11):1353-1356. 被引量:4