高大平房仓入库高水分晚籼稻谷通风降水试验 被引量:8

TEST OF VENTILATION AND LOWERING MOISTURE ON LATE INDICA RICE OF HIGH MOISTURE CONTENT IN LARGE WAREHOUSE
下载PDF
导出
摘要 高大平房仓入库高水分晚籼稻谷,在粮堆达到设计堆高,并完全压住一个通风孔的风道后,采用离心风机压入式通风降水。其它通风孔照此法依次进行。选择气温在19~25℃之间、气湿<70%RH时进行通风,能将16%以内的水分降到13.5%以内,并能达到保持储粮品质,保证储粮安全,节约费用的目的。 Late indica rice of high moisture content was stored in large warehouse, the height of grain bulk reached designed height,and the grain bulk completely covered the ventilation duct, centrifugal fan was used to ventilate and lower temperature. Ventilation was carried out when the atmospheric temperature was 19 - 25℃, relative humidity〈 70% RH. It can lower the moisture content from 16% to 13.5%. It can maintain the quality of grain, ensure stored- grain safety, and save costs.
出处 《粮食储藏》 2005年第4期32-34,共3页 Grain Storage
关键词 高大平房仓 高水分粮 机械通风 降水 通风孔 高水分 籼稻谷 降水试验 入库 通风降水 large warehouse, high moisture content grain, mechanical ventilation, lower moisture
  • 相关文献

参考文献4

  • 1国家粮食局.LS/T1202—2002,储粮机械通风技术规程[M].中国标准出版社,2002,12..
  • 2联建办.中央直属储备粮库粮情测控系统技术质量要求,联建办[1999]函字第40号[Z].,..
  • 3王双林,高影,张华昌,涂杰,费杏星,陈国平.稻谷在储干燥试验[J].粮食储藏,2004,33(2):32-34. 被引量:8
  • 4易世孝 盛宏贤 王丰富.高大平房仓应用离心风机分段降温试验[J].粮油仓储管理与科技信息,2004,11.

二级参考文献3

  • 1Paul Dickson, Ted Miller. Harvesting for Quality. RICE JOURNAL, 1996, Vol. 99, No. 1
  • 2Pat Bollich, Paul Dickson. On - farm drying. RICE PRODUCTION CALENDAR AND GUIDE, 1995, Vol. 98,No. 1
  • 3Renee Gannon. Maintaining Quality. RICE JOURNAL,1996, Vol99, No. 6