期刊文献+

二滩电厂工业用气系统高温故障分析与处理

High Temperature Fault Analysis and Treatment for Industrial Gas System at Ertan Hydropower Plant
下载PDF
导出
摘要 工业用气系统是水电厂一个重要的辅助系统,在风系统运行过程中,常出现的故障是高温报警、压力高报警和喷油、排气压力低、油耗大等。分析了二滩电厂风系统运行过程中出现的高温报警故障,阐述了空压机高温报警处理方法和原因。 Industrial gas system is a very important auxiliary system in hydropower plant . During operation of ventilation system , high temperature alarm, high pressure alarm and oil injection , low air discharge pressure , high oil consumption normally occur. High temperature alarm faults occurred in operation of ventilation system of Ertan hydropower plant are analyzed . Treatment method for high temperature alarm of air compressor and its causes are described in the paper.
作者 张旭阳
机构地区 二滩水力发电厂
出处 《四川水力发电》 2005年第4期65-67,共3页 Sichuan Hydropower
关键词 温控阀 断油电磁阀 温度开关 油冷却器 油过滤器 二滩电厂 故障分析 temperature control valve cut-off electromagnet valve temperature switch oil cooler oil filter Ertan Hydropower Plant fault analysis