摘要
阐述了钢筋锈蚀机理,从pH值、Cl-含量、混凝土保护层等多方面,分析了混凝土中钢筋锈蚀的影响因素,并从合理选材、提高混凝土密实度、增加保护层厚度等方面,提出了防止钢筋锈蚀的措施。
The mechanism caused the corrosion of reinforcement steel as well as its influencing factors are analyzed from PH value, concrete protective cover, content of cl^-1 and other aspects. Furthermore, from material selection, density control and other aspects corresponding prevention measures are proposed to control corrosion.
出处
《山西建筑》
2005年第18期136-137,共2页
Shanxi Architecture
关键词
钢筋锈蚀
机理
混凝土保护层