摘要
根据HL-2A装置的结构特点,提出了HL-2A装置偏滤器系统改造的基本方向。对HL-2A极向场线圈系统进行了优化设计,计算了单零平衡位形,进行了开放式偏滤器的结构设计,并对新的偏滤器系统进行了热分析和结构分析。结果表明,新的偏滤器系统新的偏滤器系统能够满足具有一定拉长比和三角形变的等离子体放电要求。
A modified way of HL-2A divertor is presented based on the characteristics of the HL-2A device. An optimum design for the poloidal field coil system is made. A single null plasma equilibrium configuration is calculated. The structure of an open divertor is introduced. Thermal and structural analyses have been made. Results show that the new divertor system can satisfy the plasma discharge for an advanced divertor configuration with some elongation and triangle.
出处
《核聚变与等离子体物理》
EI
CAS
CSCD
北大核心
2005年第3期179-182,共4页
Nuclear Fusion and Plasma Physics
基金
国家自然科学基金资助项目(19889502)