期刊文献+

应用螺旋CT三维重建颌面部软组织的研究 被引量:14

The research on 3-D maxillofacial soft tissue reconstruction by spiral CT
下载PDF
导出
摘要 目的:评价螺旋CT在颌面部软组织重建中的价值。方法:对1例右耳缺损患者的头部进行螺旋CT扫描,扫描数据以DICOM格式储存。在诊断工作站上以SSD法对图像进行重建。结果:螺旋CT能一次快速精确完成整个头部的扫描与重建,面部软组织、器官重建图像清晰,但瞳孔位置不能显示。结论:对于头面部除瞳孔以外的软组织三维重建,可选择螺旋CT三维重建方式。 PURPOSE: To evaluate the role of spiral CT in 3-D reconstruction of maxillofacial soft tissues. METHODS: Spiral CT was given to a patient who had his right ear absent. The data was recorded in DICOM format. Digital image was reconstructed on GE advantage workstation in SSD way. RESULTS: Spiral CT can quickly and precisely scan and reconstruct the whole head, the reconstructed images of facial soft tissues and apparatus were very clear, but the site of pupil can not display. CONCLUSION: Except for the pupils, spiral CT is a useful way for maxillo-facial soft tissue reconstruction. It can be widely used in hospitals. Supported by Research Fund (No.024119017) of Science and Technology Committee of Shanghai Municipality and Shanghai Leading Academic Discipline Project (T0202).
出处 《上海口腔医学》 CAS CSCD 2005年第4期330-332,共3页 Shanghai Journal of Stomatology
基金 上海市科委科研基金(024119017) 上海市重点学科(特色学科)建设项目(T0202)
关键词 螺旋CT 颌面部软组织 三维重建 Spiral CT Maxillofacial soft tissue 3-D reconstruction
  • 相关文献

参考文献7

二级参考文献27

  • 1[1]Marden E, Alder D, Thomas D,et al. Clinical usefulness of two-dimensional reformatted and three-dimensionally rendered computerized tomographic images. J Oral Maxillofac Surg, 1995, 53:375
  • 2[2]Lamber PM, Ohio DD. Three-dimensional computed tomography and anatomic replical treatment planning. Oral Surg Oral Med Oral Pathol, 1989, 68:782
  • 3[3]James Z. 3-D reconstruction for evaluation of facial trauma. ANJR, 1992, 13:893
  • 4[4]Jeffrey LM, Michael WW. The “third” dimension in craniofacial surgery. Plastic and Reconstruction Surgery, 1983, 71:759
  • 5[5]David CH, Paul LT. CT of dry skulls with craniofacial deformities: Accuracy of three-dimensional reconstruction. Radiology, 1985, 157:113
  • 6[1]Brink J A.Technical aspects of helical (spiral) CT.Radiol clin North Am,1995,33(5):825
  • 7[2]Rigauts H,Spiral scanning and the influence of reconstruction algorithm image quality comput Assist tomogr,1990,14:675
  • 8[3]Crawford CR,King KF.computed tomography scanning with simultaneous patient translation.Med Phys,1990,17(6):967
  • 9[4]Tan KB.The use of multiplanar reformatted computerised tomography in the surgical-prosthodontic planning of implant placement Ann Acad Med Singapore.1995;24(1):68
  • 10[5]Weinberg LA,Kruger B.Three-dimensional guidance system for implant insertion:Part Ⅱ.Dual axes table-problem solving.Implant Dent.1999;8(3):255

共引文献167

同被引文献202

引证文献14

二级引证文献48

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部