期刊文献+

亚铁氰化钾钛从模拟高放废液中去除Cs^+冷实验研究 被引量:10

INACTIVE EXPERIMENT ON REMOVAL Cs ̄+ FROM SIMULATED HLLW BY POTASSIUM TITANIUM HEXACYANOFERRATE
下载PDF
导出
摘要 研究了无机离子交换剂亚铁氰化钾钛从模拟高放废液中去除Cs的双柱串级冷实验。结果表明:当模拟废液中Cs的质量浓度为0.50g/l、酸浓度为1.10mol/l、流速为2.70ml/h、柱Ⅰ的穿透率大于90%时,干交换剂的交换容量为0.745mmol/g,柱Ⅱ的穿透率为1%时,双柱中干交换剂总的交换容量为0.640mmol/g。 Removal of Cs from simulated HLLW by an inorganic ion exchanger, potassium titanium hexacyanoferrate ,is studied. The results show that potassium titanium hexacyanoferrate as ion exchanger can be used for removal of Cs  ̄+ from simulated HLLW, The exchange capacity of Cs  ̄+for dried exchanger for the column Ⅰ over the breakthrough of 90% is 0.745mmol/g when Cs  ̄+concentration of feed is 0.50g/l,feed aciditity is 1.10mol/l and the flow rate is 2.70ml/h(2.03bed volumes/h).The exchange capacity for dried exchanger of two-colunms on the same conditions is 0.640mmol/g at the breakthrough of 1% in the column Ⅰ.
出处 《核化学与放射化学》 CAS CSCD 北大核心 1996年第2期100-104,共5页 Journal of Nuclear and Radiochemistry
关键词 亚铁氰化钾钛 高放废液 离子交换 Potassium titanium hexacyanoferrate Simulated HLLW Cs Ion ex changer