期刊文献+

肺癌放疗中的呼吸运动问题及解决方法 被引量:13

原文传递
导出
出处 《中华放射肿瘤学杂志》 CSCD 北大核心 2005年第5期461-463,共3页 Chinese Journal of Radiation Oncology
  • 相关文献

参考文献23

  • 1Ross CS, Hussey DH, Pennington EC, et al. Analysis of movement of intrathoracic neoplasms using ultrafast computerized tomography. Int JRadiat Oncol Biol Phys, 1990,18:671-677.
  • 2Ekberg L, Holmberg O, Wittgren L, et al. What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer? Radiother Oncol, 1998,48:71-77.
  • 3吴开良,蒋国梁,王鹏,周莉均.肺癌三维适形放射治疗靶体积确定的影响因素[J].中华放射肿瘤学杂志,2003,12(3):188-191. 被引量:36
  • 4Shimizu SS, Shirato H, Kagel K, et al. Impact of respiratory movement in the computed tomgraphic images of small lung tumors in three-dimensional (3D) radiotherapy. Int J Radiat Oncol Biol Phys,2000,46:1127-1133.
  • 5Seppenwoolde Y, Shirato H, Kitamura K, et al. Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat,measured during radiotherapy. Int J Radiat Oncol Biol Phys,2002,53:822-834.
  • 6Duan J, Shen S, Fiveash JB, et al. Dosimetric effect of respiration-gated beam on IMRT delivery. Med Phys,2003,30:2241-2252.
  • 7Engelsnan M, Damen EMF, Jaeger KD, et al. The effect of breathing and setup errors on the cumulative dose to a lung tumor. Radiother Oncol, 2001,60:95-105.
  • 8O'dell WG, Schell MC, Reynolds D, et al. Dose broadening due to target position variability during fractionated breath-held radiation therapy.Med Phys,2002,29:1430-1437.
  • 9Shinichi M, Masahiro E, Tatsuaki K, et al. Estimating uncertainties of the geometrical range of particle radiotherapy during respiration. Int JRadiat Oncol Biol Phys,2003,56:121-125.
  • 10DuanJ, Shen S, Fiveah JB, et al. Dosimetric effect of respiration-gated beam on IMRT delivery. Med Phys, 2003,30: 2241-2252.

二级参考文献15

  • 1洪应中.肺野[A].见:荣独山主编.X线诊断学:第2版[C].上海:上海科学技术出版社,1993.37-38.
  • 2Seddon B, Bidmead M, Wilson J, et al. Target volmne definition in confonnal radiotherapy for prostate cancer: quality asaumace in the MRC RT-01 trial. Radiother Oncol,2000,56:73-83.
  • 3lnternational Commission on Radiation Units and Measurements.Prescribing, recording, and reporting photon beam therapy(Supplement to ICRU Report 50) ,ICRU Report,62.Bethesda:ICRU ,2000.
  • 4Harris K, Adams H, Lloyd D, et al. The effect on apparent size of simulated pulmmonary nodules of using three standard CT window setting. Clin Radiol,1993,47:421.
  • 5Musset D,Grenier P,Carrette M,et al.Primary lung cancer staging:prospective comparative study of MR imaging with CT. Radiology, 1986,11:160-167.
  • 6Lynch D. Radiology staging in lung cencer . Lung Grocer, 1997, 18 Suppl 2:98-99.
  • 7Beatrice S, Margaret B, Jane W, et al. Target volmne definition in conformal radiotherapy for prostate cancer: quality assurance in the MRC RT-01 trial. Radiother Oncol, 2000,56:73-83.
  • 8Giraud P, Antoine M, Larrouy A, et al. Evaluation of microscopic tumor extension in non-retail-cell lung cancer for three-dimensional conformal radioation therapy planning, lnt J Radial Oneol Biol Phys ,2000 ,48:1015-1024.
  • 9Rosenzweig KE, Sire S,Mychalclczak B,et al. Elective nodal irradiation in treament of non-small cell lung cancer with lhree-dimemional conformal radiation therapy(3D-CRF). Int J Radiat Oncol Biol Phys,1999,45(1 Suppl 3):243-244.
  • 10International Conanission d Radiation Units and Measurements.Prescribing, recordlng and reporting photon beam therapy, report No50.Bethesda: ICRU, 1993.

共引文献35

同被引文献145

引证文献13

二级引证文献69

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部