摘要 The direct detection of clenbuterol(CL) in pig liver without any extraction separation at a pyrrole-DNA modified boron-doped diamond(BDD) electrode is reported. The pyrrole-DNA modified BDD electrode has a strong electrocatalytic effect on the redox reaction of CL. One oxidization and two reduction peaks of CL appear at 340. 2, 299. 8 and 166. 6 mV( versus SCE), respectively. The pyrrole polymer alone cannot electrocatalyze the above reaction at a BDD electrode ; the electrocatalytic effect of a BDD electrode modified with DNA membrane is unsufficient for the analytical detection of CL; the replacement of boron-doped diamond by glass carbon makes the electrocatalytic reaction impossible ; the redox process is pH dependent. The influences of various experimental parameters on the pyrrole-DNA modified BDD electrode were investigated. A sensitive cyclic vohammetric response for CL was obtained in a linear range from 3.4 × 10^-6 to 5 × 10^ -4 mol/L with a detection limit of 8.5 × 10^-7 mol/L. A mean recovery of 102. 7% of CL in the pig liver sample solution and a reproducibility of 3.2% were obtained. The direct detection of clenbuterol(CL) in pig liver without any extraction separation at a pyrrole-DNA modified boron-doped diamond(BDD) electrode is reported. The pyrrole-DNA modified BDD electrode has a strong electrocatalytic effect on the redox reaction of CL. One oxidization and two reduction peaks of CL appear at 340. 2, 299. 8 and 166. 6 mV( versus SCE), respectively. The pyrrole polymer alone cannot electrocatalyze the above reaction at a BDD electrode ; the electrocatalytic effect of a BDD electrode modified with DNA membrane is unsufficient for the analytical detection of CL; the replacement of boron-doped diamond by glass carbon makes the electrocatalytic reaction impossible ; the redox process is pH dependent. The influences of various experimental parameters on the pyrrole-DNA modified BDD electrode were investigated. A sensitive cyclic vohammetric response for CL was obtained in a linear range from 3.4 × 10^-6 to 5 × 10^ -4 mol/L with a detection limit of 8.5 × 10^-7 mol/L. A mean recovery of 102. 7% of CL in the pig liver sample solution and a reproducibility of 3.2% were obtained.
出处 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2005年第5期517-521,共5页 高等学校化学研究(英文版)
基金 Supported by the National Natural Science Foundation of China(Nos. 20435010, 20375012, 20205005 and 20475014).
关键词 Pyrrole-DNA modified boron-doped diamond(BDD) electrode Clenbuterol( CL) Animal liver Cyclic voltammetry Pyrrole-DNA modified boron-doped diamond(BDD) electrode, Clenbuterol( CL), Animal liver, Cyclic voltammetry
  • 相关文献

参考文献18

  • 1Smith D. J. , J. Agric. Food Chem. , 2000, 48, 6036.
  • 2Traynorl. M., Crooks S. R. H., Bowers J., et al. , Anal.Chim. Acta, 2003, 483, 187.
  • 3Vyncht G. V., Preece S., Gaspar P., J. Chrom. A, 1996,750. 43.
  • 4Song Y., Wang D., Hu Y. , et al. , J. Pharm. and Biomed.Anal. , 2003, 31, 311.
  • 5Lin L. A. , Tomlinson J. A. , Satzger R. D. , J. Chrom. A,.1997, 762, 275.
  • 6Keskin S., Ozer D., Temizer A., J. Pharm. and Biomed.Anal. , 1998, 18, 639.
  • 7Lopez-Erroz C., Vinas P., Cerdan F. J., et al., Talanta,2000, 53, 47.
  • 8Carducci C. N. , Lucangioli S. E. , Rodriguez V. G. , et al. ,J. Chrom. A, 1996, 730, 313.
  • 9Sawaya W. N. , Lone K. , Husain A. , et al. , Food Control,2000, 11, 1.
  • 10Crescenzi C. , Bayoudh S. , Cormack P. A. G. , et al. , Anal.Chem. , 2001, 73, 2171.