摘要
目的:探讨溶血对血清蛋白电泳结果的影响。方法:用Sebia电泳仪分别测定未溶血、轻度溶血、中度溶血、重度溶血标本,对结果进行统计学分析。结果:轻度溶血时P>0.05,差异无显著性,但中、重度溶血时影响Albumin、Alpha-2及Beta区带,结果差异有显著性。结论:轻度溶血结果可以参考,但不应用中、重度溶血标本进行蛋白电泳。
Objective:To discuss the influence of hemolysis on human serum protein electrophoresis. Methods:The hydrasys of Sebia was adapted for measuring normal samples and slightly,medium and heavy hemolytic samples.The results were compared with statistics. Results: When hemolysis is slightly, the results had not significant difference (P〉0.05), but medium and heavy hemolysis would irdluenee albumin,alpha-2 and beta section of eleetrophoretie samples,with significant difference. Conclusion: The results of slightly hemolytic samples can supply references to clinic. Do not use medium and heavy hemolytic samples in protein electrophoresis.
出处
《现代医药卫生》
2005年第18期2413-2414,共2页
Journal of Modern Medicine & Health
关键词
溶血
血清蛋白电泳
Hemolysis
Serum protein eleetrophoresis