摘要 目的比较评价医疗产品细胞毒性的3种方法,即MTT法、活细胞计数法及形态观察法。方法用MTT法、活细胞计数法及形态观察法对19种医疗产品进行细胞毒性测试,并对样品毒性分级及作出合格与否的判断,比较这些方法之间的符合程度及在检测细胞毒性方面各自的优缺点。结果MTT法与活细胞计数法的毒性级别判断符合率为73.7%(14/19),判断样品合格与否,两者符合率为94.7%(18/19),15号样品MTT法毒性级别判为4级,但细胞形态观察法发现细胞形态正常,贴壁生长良好,结果与活细胞计数法一致。重复3次检测,仍出现这种现象。结论MTT法操作简便,人为误差小,更适于多种医疗产品的同时检测,但对于MTT检测不合格产品要结合活细胞计数法及形态观察法,作出综合判断。 Objective To compare three methods (MTT assay, living cells count and morphologic observation) for evaluation on cytotoxicity of medical products. Methods MTT assay, living cells count and morphologic observation were used to evaluate the cytotoxicity of nineteen pieces of medical products by cytotoxicity graduation and judgement of qualification, the results of these methods were analysed for degree of coincidence and comparison of advantages and disadvantages among these methods. Results The rate of coincidence of cytotoxicity graduation between MTT assay and living cells count was 73.7% (14/19) and that of qualification was 94.7% (18/19), the sample No. 15 was tested four times with three methods, and the results show the difference between MTT assay and living cells-count were great, while the results of morphologic observation method were concordant with that of living cells count. Conclusion MTT assay is more suitable for evaluation of cytotoxicity of medical products for it is easy to operate and its errors are small, but living cells-count method and morphologic observation are needed to make a comprehensive judgement to unqualified medical products.
出处 《苏州大学学报(医学版)》 CAS 北大核心 2005年第4期605-608,共4页 Suzhou University Journal of Medical Science
关键词 MTT法 活细胞计数法 形态观察法 医疗产品 细胞毒性 MTT assay living cells count morphologic observation medical products cytotoxicity
  • 相关文献

参考文献5

  • 1Harmand M F. In vitro study of biodegradation of Co-Cr alloy using a human cell culture mode[J ]. J Biomater Sci Polym Ed, 1995, 6(9) :809.
  • 2贾文英,史弘道.细胞毒性试验评价医用装置生物相容性的研究概况[J].实用美容整形外科杂志,2001,12(5):253-255. 被引量:22
  • 3GB/T16886.5-1997.医疗器械生物学评价.第五部分:细胞毒性试验:体外法[S].[S].,..
  • 4杨吉成 宋礼华 周建华.医用细胞工程[M].上海:上海交通大学出版社,2001.92.
  • 5GB/T14233.2-93.医用输液、输血、注射器具检验方法第二部分:生物试验方法[S].[S].,..

二级参考文献2

  • 1宋淑华 卢英 等.医用硅橡胶聚乙烯的细胞毒性试验[J].中国生物医学工程报,1988,7(21):98-98.
  • 2-.ASTM标准年鉴医用装置标准[M].成都:科技大学出版社,1991.343.

共引文献28

同被引文献50

  • 1Dekun Zhang~1, Junjie Duan~1, Dagang Wang~2, Shirong Ge~2 1. School of Materials Science and Engineering, China University of Mining and Technology Xuzhou 221116, P. R. China 2. School of Mechanical and Electrical Engineering, China University of Mining and Technology, Xuzhou 221116, P. R. China.Effect of Preparation Methods on Mechanical Properties of PVA/HA Composite Hydrogel[J].Journal of Bionic Engineering,2010,7(3):235-243. 被引量:8
  • 2郑策,梅丹,杜小莉,李大魁.细胞毒类化疗药品等危险药品的处置与防护[J].中国药房,2004,15(8):471-473. 被引量:8
  • 3李毅,李少萍.聚乳酸-甲壳素接骨板的体外细胞毒性研究[J].南方医科大学学报,2007,27(1):65-68. 被引量:6
  • 4由少华,王昕,黄经春,等.医疗器械生物学评价.第5部分:体外细胞毒性试验[S].北京:中国标准出版社,2003:84-88.
  • 5Klara P M, Ray C D. Artificial nucleus replacement: clinical experience [ J ]. Spine, 2002, 27 (12) : 1374 - 1377.
  • 6Bao Q B, Yuan H A. New technologies in spine : nucleus replacement [J]. Spine, 2002, 27(11):1245-1247.
  • 7Di-Martino A, Vaccaro A R, Lee J Y ,et al. Nucleus pulposus replacement: basic science and indications for clinical use[ J]. Spine, 2005, 30( 16 Suppl) : S16 - S22.
  • 8Goins M L, Wimberley D W, Yuan P S, et al. Nucleus pulposus replacement : an emerging technology [ J ]. Spine J, 2005, 5 (6 Suppl) : 317S-324S.
  • 9Fu T S, Lai P L, Tsai T T, et al. Long-term results of disc excision for recurrent lumbar disc herniation with or without posterolateral fusion [ J ]. Spine, 2005, 30 (24) :2830 - 2834.
  • 10Hoogland T, van-den-Brekel-Dijkstra K, Schubert M, et al. Endoscopic transforaminal discectomy for recurrent lumbar disc hemiation : a prospective, cohort evaluation of 262 consecutive cases [ J ]. Spine, 2008, 33(9) : 973 -978.

引证文献6

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部