摘要
本论文介绍了小巧型电吹风两种基本的工作原理,并给出了一种类型的电吹风的完整电路,分析其在安规试验中常见的几种不合格项,主要有非正常试验不合格,爬电距离、电气间隙不合格。具体的整改措施有:选用合适自复位热断路器、外壳用耐火耐热型塑料、合理布置导线、电源线连接改进设计等。
The paper introduced two basic principle of Hair Dryer and provided a type of intact circuit and analyzed its several disqualifications in safety test. The main disqualifications come from: abnormal test, creepage and clearance distance. This paper brings forward improvement measure: selecting suitable serf-resetting thermal cut-out , using resisting fire-plastic in crust, laying wire appropriately , changing connecting in power supply design.
出处
《中国测试技术》
2005年第5期76-78,共3页
CHINA MEASUREMENT & TESTING TECHNOLOGY
关键词
电吹风检测
原理图
不合格项
整改措施
非正常试验
Hair dryer test
Principle figure
Disqualification
Improved measure
Abnormal test