期刊文献+

铝合金中磷的测定 被引量:3

Determination of phosphorous in aluminium alloy
下载PDF
导出
摘要 采用盐酸溶解铝合金试样,高氯酸冒烟将磷氧化成正磷酸在0.42mol·L盐酸介质中,用抗坏血酸还原为铋磷钼蓝进行光度测定。经过条件试验,基体不干扰测定。对合成试样进行测定,回收率在91%-105%之间。该方法操作简便,结果准确可靠。 The sample was dissolved by HCl. Phosphorus was oxidized to phosphoric acid, which was then reduced to molybdobismuthy phosphoric acid in mediator of 0.42 mol·L^-1 HCl by ascorbic acid and then phosphorus was determinated by spectrophotometric method. The associated sample was also determinated. Recovery rate is at 91%-105%. The method is easy to operate and has high accuracy and precision.
作者 李建舫
出处 《兵器材料科学与工程》 CAS CSCD 北大核心 2005年第5期48-50,共3页 Ordnance Material Science and Engineering
关键词 铝合金 分光光度计 测定 aluminium alloy phosphorus speetrophotometry method