摘要 应用理论分析和试验的方法,研究了热膜式空气质量流量传感器的静态响应和动态响应特性。通过对传感器单元在非稳定气流情况下存在的热滞后现象的分析,推导出恒流和恒温测量法的时间常数表达式,并对影响时间常数的各种因素和测量补偿方法进行了讨论。结果表明,恒温法的时间常数比恒流法小2g(Rr-1)倍;恒温法的动态响应取决于反馈效率,如果使反馈过程迅速有效,便可实现对热滞后的瞬时补偿;恒温法热膜式空气质量流量计不易污染,测量精度较高,动态响应好,使用方便。 This paper studied the frequency response of hot-film air mass flow sensors by the theoretical analysis and experimental research methods. The expression of the time-constant was derived by analyzing the phenomena of heat-delay in sensor unit under gas unsteady flow. And the all sorts of influence factors for the time-constant and also the compensation methods were dis- cussed. The results indicate that the time-constant with constant temperature measuring method is 2g(Rr,-1) times less than that with constant electric current measuring method, and the frequency response with constant temperature measuring method is decided by the feedback efficiency. If feedback process is very quick and effective, the instantaneous compensation can be realized for the heat-delay with constant temperature measuring method. 4 figs, 6 refs.
作者 吴克刚
出处 《长安大学学报(自然科学版)》 EI CAS CSCD 北大核心 2005年第5期99-102,共4页 Journal of Chang’an University(Natural Science Edition)
关键词 汽车工程 发动机 空气质量流量 热膜传感器 动态响应 automobile engineering engine air mass flow hot-film sensor frequency response
  • 相关文献

参考文献5

二级参考文献6

  • 1杨世铭.传热学[M].高等教育出版社,1987,10..
  • 2LOESING K H.Mass air flow meter-design and app-lication[J].SAE Paper 890779,1989.
  • 3SAUER R.Hot-film air mass meter-a low-coast app-roach to intake air measurement[J].SAE Paper 880560,1988.
  • 4SUMAL J S.Bosch mass air flow meter:Status and further aspects[J].SAE Paper 840137,1984.
  • 5WU Ke-gang.Design of digital fuel-consumption me-ter[J].Journal of Xi′an Highway University,1998,18(Sup):218-220.
  • 6方建淳.8098单片机原理与应用技术[M].天津:天津科学技术出版社,1990..

共引文献19

同被引文献76

引证文献12

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部