摘要
Shot Pro遥爆系统是目前大型地震勘探仪器配备的主流同步震源控制设备,已被广泛使用。本文是总结长期的实践经验,对Shot Pro遥爆系统常见故障进行的归纳分类,并从原理上对常见故障现象进行了细致的分析,总结出了排除各种故障的具体办法。并绘制了故障检修流程图,详细阐述了实际维修过程中所采取的措施。
Shot Pro blaster system is a dominant synchronous source-controlling apparatus equipped in current large-scale seismographs, which has been widely used. Based on long-period practical experiments, the paper clarified and categorized the common faults of Shot Pro blaster system, analyzed in detail common faults in principle and summarized concrete methods for eliminating different faults. The flow chart of checkup and maintenance was also drawn and the measures adopted in a process of practical maintenance were expounded in detail in the same time.
出处
《物探装备》
2005年第3期186-193,共8页
Equipment for Geophysical Prospecting