摘要 从分析Terfenol-D材料的磁致伸缩机理出发,引申出预应力和偏置磁场是影响超磁致伸缩致动器性能的重要因素。零偏置磁场驱动下不同预应力对致动器位移输出影响的实验和零预应力下两种偏置磁场对致动器输出性能的比较实验,验证了合理选择预应力和偏置磁场可有效地改善致动器性能的论点。预应力和磁偏置的实验矩阵确定了不同预应力对应的优化偏置磁场,实际设计中需根据致动器要求确定优化的偏置条件。 This paper pointed out that prestress and magnetic bias were important factors to impact the performances of actuators, according to the theory of magnetorstriction. From the experiments of different prestresses without magnetic bias and different magnetic biases without prestress, it was deduced that the actuator output can be improved significantly by appropriate prestress and magnetic bias. The optimized magnetic biases corresponding to different prestresses were ascertained through the experimental matrix. The optimized prestress and magnetic bias should be defined depen ding on the performance demands of actuators in the actual actuator design.
机构地区 浙江大学
出处 《中国机械工程》 EI CAS CSCD 北大核心 2005年第18期1603-1606,共4页 China Mechanical Engineering
基金 国家自然科学基金资助项目(50105019)
关键词 磁致伸缩 预应力 磁偏置 TERFENOL-D magnetostrictive prestress magnetic bias Terfenol-D
  • 相关文献

参考文献3

  • 1Clark A E. Magnetostrictive Rare Earth-Fe2 Compounds. Amsterdam: North- Holland Publishing Company, 1980
  • 2赵仑,任冲.稀土超磁致伸缩材料的应用研究现状[J].湛江海洋大学学报,2003,23(3):77-80. 被引量:2
  • 3Clark A E, Spano M L, Savage H T. Effect of Stress on the Magnetostriction and Magnetization of Rare Earth-Rel. 95 Alloys. IEEE Transactions on Magnetics, 1983,19(5) :1964~1966