摘要 本文研究了无 UVW 位置信号检测的永磁同步电机控制方法。电机启动过程分析表明转子初始位置确定是问题的关键。本文提出了两种不同负载类型传动系统的电机转子初始位置的确定方法,并在一类实际系统中得到实现。结果表明本方法是可行的。 Without detecting the UVW's position, a control method of permanent magnet synchronous motor was investigated in this paper. The analysis of the starting process of PMSM indicates that determining the initial rotor position is the key. For two drive systems having different load, in this paper, two methods to determine the initial rotor position were proposed and realized in some kind of actual system. The results show that the methods are feasible.
机构地区 华中科技大学
出处 《电气自动化》 北大核心 2005年第5期9-10,共2页 Electrical Automation
关键词 永磁同步电机 磁场定向控制 位置检测 permanent magnet synchronous motor field oriented control position detection
  • 相关文献

参考文献2

  • 1Kiyoshi Ohishi, Yusuke Nakamura. High Performance Current Sensorless Speed Servo System of PM Motor Based on Current Estimation, in Proc. Rec[J]. IEEE-IAS Annu. Meeting, 2001:1240-1246.
  • 2Shigeo Morimoto, Masayuki Sanada, Yoji Takeda. High-Performance Current-Sensorless Drive for PMSM and SynRM With Only Low-Resolution Position Sensor[J]. IEEE transactions on industry application, 2003, 39 (3):792 - 800.