摘要
采用光助Fenton氧化、化学絮凝法联合处理生物难降解的R盐废水,考察了不同反应条件对处理效果的影响。试验结果表明,光助Fenton氧化、化学絮凝法联合处理废水,两者之间存在协同作用,可以提高处理效果,降低处理成本。在最佳试验条件下,R盐废水经光助Fenton氧化、化学絮凝法联合处理后,COD去除率可达90%以上。
The treatment of R salt wastewater with photo-assisted Fenton and flocculation process was preliminarily studied. Factors affecting wastewater treatment were investigated. The results showed that the two processes have a synergistic treatment effect. Using the photo-assisted Fenton and flocculation process can make the efficiency of COD removal better and lower the cost of treatment. In the optimal condition, the COD removal of R salt wastewater is more than 90% after the treatment with photo-assisted Fenton and flocculation process.
出处
《环境污染治理技术与设备》
CSCD
北大核心
2005年第9期58-61,共4页
Techniques and Equipment for Environmental Pollution Control
基金
高等学校博士学科点专项科研基金资助项目(20020284044)