摘要 采用正交试验法分析评价浸没式平板膜-生物反应器操作运行条件对膜污染的影响.试验选择了影响膜污染的3个主要因素,结果表明各因素对膜污染的主次关系为:污泥浓度>抽停时间比>曝气强度;其优化的操作条件为:污泥浓度5 500 mg/L,抽停时间比10∶4,曝气强度0.3 m3/h.试验同时测定了各部分膜阻力的分布情况,结果表明,外部阻力是膜阻力的主要组成部分,因而设法减轻泥饼层或凝胶层的沉积是减轻膜污染的重要手段. An orthogonal array design was adopted to analyze the various operational parameters on membrane fouling in a submerged flat sheet membrane bioreactor. The order of the operational factors according to the importance to the membrane fouling should be the sludge concentration, the ratio between suction time, nonsuction time, aeration intensity. The optimum parameters are sludge concentration 5 500 mg/L, the ratio between suction time, and nonsuction time 10:4 and the aeration intensity 0.3 m^3/h. The distribution of the various resistance was also analyzed. Test results indicated that the main part was the outside resistance, so to alleviate the aggradation of sludge cake and gelatin folium was an important measure.
出处 《膜科学与技术》 CAS CSCD 北大核心 2005年第5期26-30,共5页 Membrane Science and Technology
基金 国家高技术研究发展计划(863)项目(2002AA601220)
关键词 平板膜生物反应器 膜污染 废水处理 flat sheet membrane bioreactor membrane fouling wastewater treatment
  • 相关文献

参考文献11

  • 1Hong S P, Bae T H, Tak T M, et al. Fouling control in activated sludge submerged hollow fiber membrane bioreactors[ J ]. Declination, 2002 ,143 : 219 - 228.
  • 2Lee Wontae, Kang Seoktae, Shin Hangsik. Sludge characteristics and their contribution to microfiltration in submerged membrane bioreactors [ J ]. J Membr Sci, 2003,216: 217 - 227.
  • 3Ueda Tatsuki, Hata Kenji, Kikuoka Yasuto, et al. Effects of aeration on suction pressure in a submerged membrane bioreactor[J]. Wat Res, 1997,31(3) :489- 494.
  • 4封莉,张立秋,吕炳南.污泥浓度对膜生物反应器运行特性的影响研究[J].哈尔滨工业大学学报,2003,35(3):307-310. 被引量:46
  • 5Ozaki Noriatsu, Yamamoto Kazuo. Hydraulic effects on sludge accumulation on membrane surface in crossflow filtration[J]. Wat Res 2001,35(13) :3137 - 3146.
  • 6桂萍,黄霞,陈颍,文湘华,钱易.膜-生物反应器运行条件对膜过滤特性的影响[J].环境科学,1999,20(3):38-41. 被引量:71
  • 7夏明芳,张利民,吴志超.平片膜生物反应器中膜污染特性的实验研究[J].江苏环境科技,2002,15(3):1-3. 被引量:8
  • 8徐仲安,王天保,李常英,暴丽艳,马青梅,苗玉宁.正交试验设计法简介[J].科技情报开发与经济,2002,12(5):148-150. 被引量:301
  • 9国家环保局.水和废水监测分析方法[M].北京:中国环境科学出版社,1989.260-263.
  • 10章非娟.水污染控制工程试验[M].北京:高等教育出版社,1987.14-22.

二级参考文献15

共引文献671

同被引文献167

引证文献12

二级引证文献193

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部