期刊文献+

提高LiF:Mg,Cu,P热释光探测器热稳定性和降低残余信号的研究 被引量:2

The study of improving the stability to heat treatment and reducing the residual signal of LiF:Mg,Cu,P
下载PDF
导出
摘要 通过改变杂质Mg和Cu的浓度的方法,制备了一种新的LiF:Mg,Cu,P探测器,在不退火重复使用中灵敏度稳定的前提下,降低了残余信号.在250~270℃范围内,退火10min时,发光曲线形状没有发生明显的变化,且灵敏度保持稳定.灵敏度约为GR-200A的一半,TLD-100的30多倍,退火温度和读出温度可以提高到260℃,重复使用灵敏度保持稳定;残余信号小于0.2%,约为GR-200A的1/5.保持了GR-200A的主要优点,且具有较低的残余信号和较好的热稳定性. This new LiF:Mg,Cu,P allows temperature treatments above 240℃to reduce the residual signals on condition that its thermoluminescent response keeps stable in re-use cycles without the necessity of an initialisation procedure. The glow curve shape shows minimal differences and the sensitivity remains stable when annealed in the range from 250℃to 270℃ for 10 min. The TL sensitivity to gamma radiation is about half in that of GR-200A and 30 times higher than that of TLD-100. The residual signal is less than 0. 2% following a 260℃ readout for 12s at a heating rate of 15℃/s, which is roughly 5 times lower than that of the standard LiF.Mg,Cu,P(GR-200A). The TL response at 260℃ is reproducible within a coefficient of variation of 2 % over ten re-use cycles without systematic decrease. The new samples remain the main advantages of GR-200A phosphor, and have lower residual signal and bet- ter stability to heat treatment.
作者 崔辉 唐开勇
机构地区 防化研究院
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2005年第5期536-539,535,共5页 Nuclear Electronics & Detection Technology
关键词 LiF:Mg Cu P 退火 热稳定性 残余信号 LiF.. Mg,Cu ,P annealing, stability to heat treatment residual signal
  • 相关文献

参考文献9

  • 1Nakajima T, et al. Development of a new highly sensitive LiF thermoluminescence dosimeter and its applications[J]. Nucl Instrum Methods,1978, 157:155.
  • 2Akeselrod, MS, et al. Highly Sensitive Thermo luminescent Anion-Defective α-Al3O2 :C sigle Crystal Detectors[J]. Radiat Prot Dosim, 1990,32 (1):15-20.
  • 3Prokic M,et al. Comparison of Main Thermoluminescent properties of Some TL Dosimeters[J]. Radiat Prot Dosim, 1992,47(1-4):195.
  • 4Wang S, et al. Newly developed highly sensitive LiF(Mg,Cu ,P) TL chips with high signal-to-noise radio[J]. Radiat Prot Dosim,1986, 14:223.
  • 5Bilski P, et al. A Systematic Evaluation of The Dependence of Glow Curve Structure on The Concentration of Dopants in LiF : Mg,Cu, P[J]. Radiat Prot Dosim,1996, 65:195.
  • 6Tang KY, et al. The Application of Computerised Analysis of Glow Curvet To Personal Dosimetry in LiF: Mg, Cu, P[J]. Radiat Prot Dosim, 2002,101:239.
  • 7Tang K,et al. An Improved LiF.. Mg, Cu, P Chip With a Low Residual Signal [J]. Radiat Prot Dosim, 1999, 84:227.
  • 8Tang Kaiyong, et al. Thermal Loss and Recover of Thermoluminescence Sensitivity in LiF : Mg, Cu, P[J]. Radiat Prot Dosim, 2000, 90:449.
  • 9GB10264—88.个人和环境监测用热释光剂量测量系统[s].[S].,..

同被引文献9

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部