期刊文献+

高效液相色谱-荧光法测定布美他尼片中主药的含量 被引量:2

Content Determination of the Principal Agent in Bumetanide Tablets by HPLC-Fluoremetry
下载PDF
导出
摘要 目的:建立以高效液相色谱-荧光法测定布美他尼片中主药含量的方法。方法:色谱柱为KromasilC18,流动相为乙腈-水(50∶50),荧光检测激发波长为228nm、发射波长为418nm,内标为萘啶酸,流速为0.6ml/min,进样量为20μl,柱温为室温。结果:布美他尼检测浓度在16.75~335.00μg/ml范围内线性关系良好(r=0.9997),平均回收率为99.26%(RSD=0.49%,n=3)。结论:本方法可用于布美他尼片中主药的含量测定,且操作简便、结果准确。 OBJECTIVE: To establish a method for content determination of the principal agent in bumetanide tablets by HPLC- fluoremetry.METHODS: HPLC fluoremetry was carried out using a Kromasil C18 column and a mobile phase consisting of acetonitrile- water(50 : 50), the fluorescence detector of 228nm for excitation and 418nm for emission was used,the internal standard was dixiben,the flow rate was 0.6ml/min, the sample size was 20bd, the column temperature was the same as room temperature. RESULTS:The concentration of bumetanide was linear in the range of 16.75-335.00μg/ml( r = 0.9 997), the average recovery was 99.26% (RSD = 0.49%, n = 3) .CONCLUSION:The present method is convenient and reliable,which can be used for content determination of the principal agent in bumetanide tablets.
作者 唐坤
出处 《中国药房》 CAS CSCD 北大核心 2005年第19期1493-1494,共2页 China Pharmacy
关键词 高效液相色谱-荧光法 布美他尼 含量测定 HPLC fluoremetry Bumetanide Content determination
  • 相关文献

参考文献2

  • 1Wells TG, Hendry IR, Kearns GL.Measurement of bumetanide in plasma and urine by high-performance liquid chromatography and application to bumetanide disposition[J].J Chromatogr, 1991, 570(1): 235.
  • 2Bokens H, Bourscheidt C, Muller RF.Determination of bumetanide in plasma by high-performance liquid chromatography[J].J Chromatogr, 1988, 434(1): 327.

同被引文献34

  • 1唐坤.高效液相色谱-荧光法测定人血浆布美他尼浓度[J].医药导报,2005,24(11):1002-1003. 被引量:1
  • 2朱炳辉,吴西梅,龙朝阳,李敏.减肥保健品中8种化学药物的固相萃取-液相色谱/质谱法测定研究[J].分析科学学报,2007,23(4):378-382. 被引量:14
  • 3L.S. Goodman, A. Gilman. The Pharmacological Basis of Therapeutics, 9th Edition[M]. New York: McGraw-Hill, 1996.
  • 4Politi L, Morini L, Polettini A. A direct screening procedure for diuretics in human urine by liquid chromatography-tandem mass spectrometry with information dependent acquisition[J].Clinical Chima Acta, 2007, 386(1-2): 46-52.
  • 5Xinyu Zheng, Minghua Lu, Lan Zhang, et al. An online field-amplification sample stacking method for the determination of diuretics in urine by capillary electrophoresis-amperometric detection[J]. Talanta, 2008,76: 15-20.
  • 6V. Morra, P. Davit, P. Capra, et al. Fast gas chromatographic/mass spectrometric determination of diuretics and masking agents in human urine Development and validation of a productive screening protocol for antidoping analysis[J]. Journal of Chromatography A, 2006, 1135:219-229.
  • 7Petr Solich, Christoforos K. Polydorou, Michael A. Koupparis, et al. Automated flow injection fluorimetric determination and dissolution studies of bumetanide in pharmaceuticals[J]. Analytica Chimica Acta, 2001,438:131-136.
  • 8I F. Badoud, E. Grata, L. Perrenoud, et ai. Veuthey. Fast analysis of doping agents in urine by ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometryl Screening analysis[J]. Journal of Chromatography A, 2009, 1216 : 4423-4433.
  • 9Jiaming Liu, Liqing Zeng, Zhiming Li, et al. Solid substrate-room temperature phosphorimetry for the determination of residual elenbuterol hydrochloride based on the catalysis of sodium periodate oxidizing cosine Y[J]. Analytica Chimica Acta 2009, 638: 69-74.
  • 10Y. X. Ci, T. Z. Zhou. Multivariate Complex in the Analytical Chemistry[M]. Beijing: Science Press, 1999.

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部