期刊文献+

微型IgG免疫传感器的制备及其对人免疫球蛋白G的响应 被引量:4

Preparation of a Micro Immunoglobulin G Immunosensor and Its Highly Sensitive Potentiometric Response to Human Immunoglobulin G
下载PDF
导出
摘要 以硅烷醇-戊二醛交联法在Ag电极表面制备的抗IgG膜电极为敏感器件,配以Ag/AgCl参比电极制备成微IgG免疫传感器.传感器基于免疫反应的原理,通过其电动势的变化对IgG的Nernst响应,测定人免疫球蛋白(hIgG)的含量.采用两种抗IgG膜电极的传感器,对hIgG的响应时间均小于6 min;线性范围在0.20~2.0 μg/L,检出限为0.1 μg/L.直接检测健康人血清中hIgG 的相对标准偏差为6.2% (n=5);加标回收率为93%~108%.以0.012 mol/L盐酸为再生液,传感器可重复使用,对IgG的活性在4℃可保持30 d. A micro immunoglobulin G(IgG) immunosensor has been prepared by means of covalent immobilization of anti-IgG on a silver electrode and its highly sensitive Nernst response to human immunoglobulin G (hlgG) has been investigated. This potentiometric response is based on the change in the electrode potential before and after the antigen-antiboby reaction. The response time of immunosensor prepared with two anti-IgG electrodes is less than 6 min. The correlation coefficients of the response to hlgG are 0.997 and 0. 995 in the concentration range of 0.2 - 2.0 μg/L with the detection limit of 0. 1 μg/L, respectively. The relative standard deviation (RSD) is less than 6.2% ( n = 5 ) and the recovery is in the range of 93% - 108% for the determination of human serum. The immunosensor can be repeatedly used after activation of regenerative reagent and its activation may maintain more than 30 days in the circumstance of4℃.
出处 《分析化学》 SCIE EI CAS CSCD 北大核心 2005年第10期1476-1478,共3页 Chinese Journal of Analytical Chemistry
关键词 免疫传感器 抗体 抗原 IGG 响应时间 表面制备 免疫球蛋白G Ag/AgCl 微型 戊二醛交联法 Immunosensor, antigen, antibody, immunoglobulin G
  • 相关文献

参考文献7

  • 1Ghindilis A L, Atanasov P, Wilkinst M. Biosensors & Bioelectronics, 1998, 13: 113~131.
  • 2Lin J H, Ju H X. Biosensors & Bioelectronics, 2005, 20: 1461~1470.
  • 3Aizawa M, Morioka A, Suzuki S. Anal. Biochem., 1979, 94: 22~28.
  • 4Alexander P W, Mahaoltra C. Anal. Chem., 1982, 54: 68~71.
  • 5Klein M, Kates R, Chucholowski N. Sensors & Actuators, 1995, B26~27: 474~476.
  • 6丁兆红,赵常志,辛军华,冯春梁.电位型无标记IgG免疫探针[J].辽宁师范大学学报(自然科学版),2001,24(4):386-388. 被引量:3
  • 7Yamamato N. Clin. Chem., 1980, 26: 1569~1575.

二级参考文献4

  • 1[1]AIZAWA M,MORIOKA A, SUZUKI S,et al . Enzyme Immunosensor [J].Aanl Biochem,1979,94(1):22-28.
  • 2[2]ALEXANDER P W,MALTRA C.Enzyme-Linked Immunnoessay of human Immunoglobulin G with the Fluoride Ino Selective Electrode [J].Anal Chem, 1982,54(1):68-71.
  • 3[3]FONONG T,RECHNITS G A.Honogeneous Potentiometric Enzyme Immunoassay for Human Immunogolbulin G[J].Anal, Chem,1984,56(13):2586-2590.
  • 4[4]KWANG DIM ,YOUNG OK PARD,HYUN IA CHUN,Interaction of Corticosterone Antibody and Glutaraldehyde Adsorbed on Pt Electrodes Modified with Silane[J]. Anal Science, 1996,12(2) :327-330.

共引文献2

同被引文献596

引证文献4

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部