摘要
湛江发电厂3号机旁路调节系统因高压抗燃油颗粒度超标,致使旁路阀不能动作。对油箱中析出的凝胶状油泥进行试验分析,制定出处理措施,实施后效果显著。
Because of particle size in high pressure fireresistant oil of bypass control system for steam turbine no.3 in Zhanjiang Power Polant exceeding standard,the bypass valve can't be actuated.The gelatinous sludge separated out in the oil tank has been tested,and treatment scheme being worked out.After implementation of the said scheme,the effectiveness is obvious.
出处
《热力发电》
CAS
北大核心
2005年第10期86-86,88,共2页
Thermal Power Generation
关键词
旁路调节系统
高压抗燃油
凝胶状油泥
减压阀
油箱
bypass control system
high pressure fireresistant oil
gelatinous oil sludge
relief valve
oil tank.