基于标准的Hanbury-Brown-Twiss探测方式下,研究了具有Poisson统计背景的实际单分子光子源与理想双分子系统的光子统计特性,通过比较分析二者在具有相同平均光子数n—时的Mandel参数,研究给出一种利用双光子的统计概率P(2)判别单分子的方法为P(2)<12(2-4-2n—)2.同时研究了单分子光子源的信号/背景比对分析结果的影响.
We theoretically study the photon counting statistics characterizations of the real single molecular photon source with a Poisson statistics background and that of an ideal double molecular system based on the standard HBT detection. Mandel parameter Q of each source with the same mean photons n^- was analyzed. We have obtained an efficient method to identify single by the two-photon statistics probability P(2), which shows the relation P(2)〈1/2(2-√4-2n^-)^2. Additionally, we molecule studied the effect of single-to-background ratio of the single molecular photon source on the criterion.
出处
《物理学报》
SCIE
EI
CAS
CSCD
北大核心
2005年第11期5116-5120,共5页
Acta Physica Sinica
基金
国家自然科学基金(批准号:60378004)
高等学校博士学科点专项科研基金(批准号:20040108002)
人事部留学人员科技活动择优资助项目
山西省留学基金资助的课题.~~