期刊文献+

COD与回流时间的相关性研究及测定方法改进 被引量:5

Improvement on the Method for Verifying Relativity of Circumfluence Time and COD
下载PDF
导出
摘要 通过以大量的数据分析了回流时间对化学耗氧量测定的影响,得出40min时水样的氧化率在97.7%~99.6%,平均为99%,可将回流时间改为40min测定COD,然后将所得结果通过系统校正,与标准法相比较,经统计检验,精密度、准确度等均符合要求,可用于批量较大、水质成份稳定的监测. This paper analyzes the influence of circumfluence time in COD with a large amount of data.Results show that at 40minute the range of the ratio of oxidation is 97.7%~99.6%,with average ratio of 98%.So the circumfluence time can be changed to 40 minutes to measure COD,then compare the data adjusted with that of standard method,its precision and accuracy are confirmed through statistical test.This method can be used in the surveillance test for large batches of wastewater with stable composition.
出处 《环境科学与技术》 CAS CSCD 北大核心 2005年第6期48-49,共2页 Environmental Science & Technology
关键词 化学耗氧量 回流时间 统计检验 COD circumfluence time statistical test
  • 相关文献

参考文献9

二级参考文献33

  • 1程秉珂,池靖,李海琼,孙莉.密封法测定COD[J].上海环境科学,1989,8(10):22-24. 被引量:4
  • 2鄂晓华,温洪旭.水中化学耗氧量的快速测定法[J].环境保护科学,1994,20(3):50-53. 被引量:3
  • 3袁洪志.COD的极谱法研究[J].环境科学与技术,1994(2):26-28. 被引量:19
  • 4韦利杭.化学需氧量快速测定法的研究[J].环境污染与防治,1995,17(3):38-41. 被引量:38
  • 5黄毅.微波密封消解法测定COD_(cr)值[J].上海环境科学,1996,15(5):32-34. 被引量:44
  • 6国家环保局水和废水监测分析方法编委会.水和废水监测分析方法[M].北京:中国环境科学出版社,1989..
  • 7-.水质分析方法.国家标准汇编[M].北京:中国标准出版社,1996..
  • 8-.环境监测分析方法(第三版)[M].北京:国家环保出版社,1997..
  • 9[1]Jones B M, Sakaji R H, Daughton C G. Comparison of Microcolorimetric and Macratitrimetric methods for Chemical Oxygen Demand of Oil Shale Wastewaters. Anal Chem, 1985, 57 (12): 2334~2337.
  • 10[4]Purnendu K, Dasgupta and Kaj petersen. Kinetic Approachto the Measurement of Chemical Oxygen Demand with an Automated Micro Batch Analyzer. Anal Chem, 1990, 62 (04): 395~402.