期刊文献+

Analysis of Pulverized Coal by Laser-Induced Breakdown Spectroscopy 被引量:8

Analysis of Pulverized Coal by Laser-Induced Breakdown Spectroscopy
下载PDF
导出
摘要 Laser-induced breakdown spectroscopy (LIBS) has been used to detect atomic species in various enviromnents. The quantitative analysis (C, H, O, N and S) of representative coal samples are being carried out with LIBS, and the effects of particle size are analyzed. A powerful pulse Nd:YAG laser is focused on the coal sample at atmosphere pressure, and the emission spectra from laser-induced plasmas are measured by time-resolved spectroscopy, and the intensity of analyzed spectral lines is obtained through observing the laser plasma with a delay time of 0.4 #s. The experimental results show that the slope of calibration curve is nearly 1 when the concentration of the analyzed element is relatively low, and the slope of curve is nearly 0.5 when the concentration of C is higher than other elements. In addition, using the calibration-free model without self-absorption effect, the results show that the decreasing of particle size leads to an increase of the plasma temperature. Laser-induced breakdown spectroscopy (LIBS) has been used to detect atomic species in various enviromnents. The quantitative analysis (C, H, O, N and S) of representative coal samples are being carried out with LIBS, and the effects of particle size are analyzed. A powerful pulse Nd:YAG laser is focused on the coal sample at atmosphere pressure, and the emission spectra from laser-induced plasmas are measured by time-resolved spectroscopy, and the intensity of analyzed spectral lines is obtained through observing the laser plasma with a delay time of 0.4 #s. The experimental results show that the slope of calibration curve is nearly 1 when the concentration of the analyzed element is relatively low, and the slope of curve is nearly 0.5 when the concentration of C is higher than other elements. In addition, using the calibration-free model without self-absorption effect, the results show that the decreasing of particle size leads to an increase of the plasma temperature.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第5期3041-3044,共4页 等离子体科学和技术(英文版)
基金 The project supported by Specialized Research Fund for the Doctoral Program of Higher Education (No. 20020487013) and bythe Key Program for International Cooperation of Science and Technology of China (No. 2001 CB711203)
关键词 laser-induced breakdown spectroscopy element analysis SELF-ABSORPTION delay time laser-induced breakdown spectroscopy, element analysis, self-absorption, delay time
  • 相关文献

参考文献11

  • 1Hwang Z W, TengYY, Li K P, et al. Appl. Spectrosc., 1991, 45:435~441
  • 2Aguilera J A, Aragon C, Campos J. Appl. Spectrosc.,1992, 46:1382~1387
  • 3Cremers D A, Radziemski L J, Loree T R. Appl: Spectrosc., 1984, 38:721~729
  • 4Wachter J R, Cremers D A. Appl. Spectrosc., 1987,41:1042~1048
  • 5Peng L W, Flower W L, Hahn D W, et al. Process Control Qual., 1995, 7:39~49
  • 6Singh J P, Zhang H, Yueh F Y, et al. Appl. Spectrosc., 1996, 50:764~773
  • 7Hahn D W, Flower W L, Hencken K R. Appl. Spectrosc., 1997, 51:1836~1844
  • 8Singh J P, Zhang H, Yueh F Y, et al. 1995, Appl.Spectrosc., 1995, 49:1617~1623
  • 9Ciucci A, Corsi M, Palleschi V, et al. Appl. Spectrosc., 1999, 53:960~964
  • 10Kuzuya M, Aranami H. Spectrochim. Acta Part B,2000, 55:1423~1430

同被引文献104

引证文献8

二级引证文献33

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部