期刊文献+

16层螺旋CT胰腺癌灌注研究 被引量:22

The Study of Tumor Perfusion in Pancreatic Carcinoma with 16-Slice Helical CT
下载PDF
导出
摘要 目的探讨正常胰腺和胰腺癌的MSCT灌注成像特征。方法30例无胰腺疾病的患者和16例经病理证实的胰腺癌患者,采用16层螺旋CT进行灌注扫描,分别测量30例正常胰腺组织和16例胰腺癌肿瘤组织及周围正常胰腺组织的血流量(BF)、血容量(BV)、平均通过时间(MTT)和表面通透性(PS)值,并进行分析。结果胰腺CT灌注的各项指标个体差异较大,但正常胰腺组织和癌周相对正常的胰腺组织的BF、BV、PS和MTT的平均值差异无显著性意义。正常胰腺组织和癌周相对正常胰腺组织的BV、BF高于胰腺癌组织,PS低于胰腺癌组织。胰腺癌周围相对正常胰腺组织与胰腺癌组织PS、BV和BF前后配对t检验差异更加明显。结论CT灌注成像技术对胰腺癌诊断具有重要的提示意义。 Objective:To evaluate the technique and application value of 16 slices spiral-CT perfusion for normal and tumorous pancreas. Methods;Perfusion CT for pancreatic cancer was performed with 16-section multi-detector row CT in 16 patients (all of them were then confirmed by pathology). 30 patients with no pancreatic disorders served as controls. Contrast medium-enhanced dynamic CT was performed,and the data were analyzed by using commercial software to calculate tissue blood flow (BF), blood volume (BV), mean transit time (MTT), and vascular permeability-surface (PS) area product. Perfusion parameters of normal pancreas, tumors tissues and the pancreatic tissues near tumors were compared. Results: There were remarkable individual differences between parameters in the CT perfusion: pancreatic cancer showed higher PS and lower BV and BF compared with those of normal pancreas. But there were no significant differences in baseline BF,BV, P$ and MTT values between normal pancreas and pancreatic tissues near tumors. However,statistical results showed more significant differences between normal pancreatic tissues and pancreatic cancer tissues. Conclusion:CT perfusion imaging can be used to identify patients with pancreatic carcinomas,because individual differences exist in the results of CT perfusion, and the changes of different parts in the same patient were more significant.
出处 《放射学实践》 2005年第10期857-860,共4页 Radiologic Practice
基金 国家"十五"科技攻关项目(2004BA714B)
关键词 体层摄影术 X线计算机 胰腺肿瘤 灌注 Tomograph, X-ray computer Pancreatic carcinoma Perfusion
  • 相关文献

参考文献6

  • 1林晓珠,缪飞,董海鹏,施卫平,陈克敏.多层面CT测量胰腺组织血流量[J].上海第二医科大学学报,2005,25(2):173-175. 被引量:13
  • 2Koseoglu K, Ozsunar Y, Taskin F, et al. Pseudolesions of Left Liver Lobe During Helical CT Examinations: Prevalence and Comparison between Unenhanced and Biphasic CT Findings[J]. Eur J Radiol, 2005,54(3):388-392.
  • 3Miles KA. Perfusion CT for the Assessment of Tumour Vascularity: which Protocol[J]. Br J Radiol, 2003,76 (9): S36-S42.
  • 4Takeda K,Mikami Y,Fukuyama S,et al. Pancreatic Ischemia Associated with Vasospasm in the Early Phase of Human Acute Necrotizing Pancreatitis[J]. Pancreas, 2005,30 (1): 40-49.
  • 5Miles KA,Hayball MP. Measurement of Human Pancreatic Perfusion Using Dynamic Computed Tomography with Perfusion Imaging [J]. Br J Radiol, 1995,68(8) :471-475.
  • 6赵心明,周纯武,吴宁,罗德红,黄遥,王建卫,孙伟,梁颖.胰腺多层螺旋CT灌注研究[J].中华放射学杂志,2003,37(9):845-849. 被引量:90

二级参考文献17

  • 1Tsushima Y, Kusano S. Age dependent decline in parenchymal perfusion in the normal human pancreas: measurement by dynamic computed tomography[J]. Pancreas, 1998, 17(2): 148-152.
  • 2Miles KA. Measurement of tissue perfusion by dynamic computed tomography[J]. BJR, 1991, 64: 409-412.
  • 3Peters AM, Gunasekera RD, Henderson BL, et al. Non-invasive measurements of blood flow and extraction fraction[J]. Nuclear Medicine Communications,1987, 8: 823-837.
  • 4Peters AM, Brown J, Hartnell GG, et al. Non-invasive measurements of renal blood flow with 99mTc DTPA: a comparison with radiolabelled microspheres[J]. Cardiovascular Research, 1987, 21: 830-834.
  • 5Bader TR, Herneth AM, Blaicher W, et al. Hepatic perfusion after transplantation: non-invasive, measurement with dynamic single-section CT[J]. Radiology, 1998, 209: 129-134.
  • 6Blomley MJK, Coulden R, Dawson P, et al. Liver perfusion studied with ulstrafast CT[J]. J Comput Assist Tomogr, 1995, 19: 424-433.
  • 7Miles KA, Hayball MP, Dixon AK. Measurement of human pancrea-tic perfusion using dynamic computed tomography with perfusion imaging[J]. BJR, 1995, 68: 471-475.
  • 8Tsushima Y, Unno Y, Koizumi J, et al. Hepatic perfusion changes after transcatheter arterial embolization (TAE) of hepatocellular carcinoma measurement by dynamic computed tomography (CT). Dig Dis Sci,1998,43:317-322.
  • 9Dugdale PE, Miles KA, Bunce I, et al. CT measurement of perfusion and permeability within lymphoma masses and its ability to assess grade, activity, and chemotherapeutic response. J Comput Assist Tomogr, 1999,23:540-547.
  • 10Hermans R, Lambin P, Van den Bogaert W, et al. Non-invasive tumour perfusion measurement by dynamic CT: preliminary results. Radiother Oncol, 1997,44:159-162.

共引文献91

同被引文献310

引证文献22

二级引证文献106

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部