本文应用国产QCJN—1型脑电波处理系统,测定20例正常人和7例颅内占位性病变(左额颞硬膜下血肿、左额多发占位性病变、左顶占位性病变,右额占位性病变、右丘脑出血,1例,脑血管造影右额脑膜瘤1例,临床诊断1例)的脑电功率谱百分比和脑电地形图。
QCJN-1 model EEG processing system have been used to measure EEGPS and BEAM iu twenty normal person and seven patients with intraeranial mass lesions (the left frontal temporal sabdural hematoma; the right thalamie hemorrhage; the right frontal, left parietal and right frontal-poly intracranial mass lesions; two rases of meningoma one diagnosed by CAG and other by clinic). The power spectrum percentage parameter of band is prevaling in each normal aged groups,.but which of δ and θ bands shows no significant difference (P>0.05 On contrast with group of patients who have intracranial mass lesion, the percentage param--i. ; of 6 and 9 bands increases more conspicuously than that of compared group (P<0.01) The location of intracranial mass lesions diagnosed by BEAM is consistent with the result of CT scan in five of seven patients and one with CAG
出处
《重庆医科大学学报》
CAS
CSCD
1989年第3期222-226,共5页
Journal of Chongqing Medical University