期刊文献+

肝脏MR灌注成像技术方法的优化研究 被引量:1

Optimization of hepatic MR perfusion imaging protocol
下载PDF
导出
摘要 目的优化肝脏MR灌注成像的扫描技术方案。方法采用单层2D FSPGR序列对40例无肝脏疾病和30例肝硬化行MR肝脏灌注扫描。将受检者随机分为4组。A、B组各含5例无肝脏病变受检者,快速团注对比剂(3.5ml/s)后连续扫描100s,A组采用经肝门单层横断面扫描,平静呼吸,B组采用单层斜冠状层面(同时包含门静脉主干、腹主动脉、肝实质),屏气状态扫描;C、D组各包含15例无肝脏病变受检者及15例肝硬化患者,均采用单层斜冠状层面扫描,平静呼吸,C组于注射对比剂后连续扫描60s;D组则连续扫描100s。分析各组受检者的时间-信号强度曲线、峰值时间和肝脏灌注指数。结果A、D组比较,采用单层斜冠位扫描方位可以避免呼吸运动导致的扫描层面的上下移动,并且避免腹主动脉的流入增强效应;B、D组比较,显示采用平静呼吸可以避免屏气后大幅度换气导致的时间-信号强度曲线(TIC)大幅度波动。C、D两组正常肝脏及肝硬化患者门静脉和肝实质峰值的时间比较均无统计意义的组间差异(P>0.05);C组肝实质TIC未显示峰段。D组正常肝脏与硬化患者的TIC峰值时间和肝脏灌注指数之间均有统计意义差异(P<0.05)。结论采用单层2D FSPGR行动态增强MR肝灌注成像时,选用斜冠状层面,平静呼吸,团注对比剂后连续扫描100s更有利于肝脏疾病患者MR灌注量化评估。 Objective To optimize the protocol of hepatic MR perfusion imaging. Methods Forty cases without liver diseases and 30 cirrhotic patients underwent hepatic MR perfusion imaging by using a single slice 2D FSPGR sequence. These cases were grouped into A, B, C and D, randomly. Group A and B contained 5 normal adults in each and were scanned for 100 s continuously after the bolus injection of Gd-DTPA. A transverse section passing the hepatic porta and quiet breath in group'A, an oblique coronal section (containing the abdominal aorta, the portal vein and the right liver lobe) and breath holding in group B. Group C and D contained 15 normal adults and 15 cirrhotic patients in each, and both used an oblique coronal section and quiet breath. 60 s scan time after bolus injection of Gd-DTPA was used in group C and 100s in group D. The time-intensity curve (TIC), peak time and hepatic perfusion index of each group were analyzed. Results Comparing group A and D, the oblique coronal scan plane could avoid the movement artifacts and the in flow enhancement effect of the abdominal aorta. Comparing group 13 and D, quiet breath could avoid the marked fluctuation of the TIC caused after breath holding. Comparing Group C and D, the 60 s scan time was not enough for the liver TIC to show its peak enhancement in Group C. Conclusion When using a single slice 2D FSPGR sequence, oblique coronal scan plane, quiet breath and 100 s scan time is more suitable for hepatic MR perfusion imaging.
出处 《中国医学影像技术》 CSCD 北大核心 2005年第10期1576-1578,共3页 Chinese Journal of Medical Imaging Technology
关键词 磁共振成像 动态增强 灌注 肝脏 血供 Magnetic resonance imaging~ Dynamic contrast enhancement Perfusion~ Liver~ Blood supply
  • 相关文献

参考文献8

  • 1张皓,沈天真,陈星荣,缪竞陶.脑DSC MR灌注成像技术方法的优化研究[J].中国医学影像技术,2004,20(7):1018-1020. 被引量:1
  • 2管生,赵卫东,周康荣,彭卫军,唐峰,毛健,曹光,孙非.大鼠肝脏MR弥散、灌注成像的初步研究[J].中国医学影像技术,2004,20(6):850-852. 被引量:16
  • 3Gianfelice D, Khiat A, Amara M, et al. MR imaging guided focused ultrasound surgery of breast cancer: correlation of dynamic contrast enhanced MRI with histopathologic findings [J]. Breast Cancer Res Treat, 2003,82(2): 93-101.
  • 4Fuentes MA, Keith CJ, Griffiths M, et al. Hepatic haemodynamics: interrelationships between contrast enhancement and perfusion on CT and Doppler perfusion indices [J]. Br J Radiol, 2002, 75(889): 17-23.
  • 5沈文,尹建忠,陈光,王鹏辉,邵立军,郭文梅,祁吉.多层螺旋CT对肝移植术后肝动脉灌注的研究[J].放射学实践,2003,18(11):816-818. 被引量:7
  • 6Ichikawa T, Haradome H, Hachiya J, et al. Characterization of hepatic lesions by perfusion-weighted MR imaging with an echoplanar sequence[J]. AJR, 1998, 170(4): 1029-1034.
  • 7Tsushima Y, Blomley MJ, Kusano S, et al. Measuring portal venous perfusion with contrast-enhanced CT: comparison of direct and indirect methods[J]. Acad Radiol, 2002,9(3) :276-282.
  • 8Van Beers BE, Leconte I, Materne R, et al. Hepatic perfusion parameters in chronic liver disease: dynamic CT measurements correlated with disease severity[J]. AJR, 2001,176(3): 667-673.

二级参考文献23

  • 1[1]Itai Y,Matsui O.Blood flow and liver imaging[J].Radiology,1997,202(2):306-314.
  • 2[2]Materne R,Van Beers BE,Smith AM,et al.Non-invasive quantification of liver perfusion with dynamic computed tomography and a dual-input one compartment model[J].Clin Sci,2000,99(6):517-525.
  • 3[3]Brix G,Bahner ML,Hoffman U,et al.Regional blood measurement with dynamic CT-initial experience[J].Radiology,1999,210(1):269-276.
  • 4[4]Miles KA,Hayball MP,Dixon AK.Functional images of hepatic perfusion obtained with dynamic CT[J].Radiology,1993,188(2):405-411.
  • 5[5]Van Beers BE,Leconte I,Materne R,et al.Hepatic perfusion parameters in chronic liver disease.Danamic CT measurements correlated with disease severity[J].AJR,2001,176(6):667-673.
  • 6[6]Ett DA,Kelley BB,Dawson P,et al.Colorectal cancer:diagnostic potential of CT measurements of hepatic perfusion and implications for contrast enhancement protocols[J].Radiology,1997,205(3):716-720.
  • 7[7]Cui D,Kiuchi T,Egawa H,et al.Microcirculationary changes in right lobe grafts in liver-donar transplantation:anear-infrared spectrometry study[J].Transplantation,2001,72(2):291-295.
  • 8[8]Charles A,Cuenod IL,Nathalie S,et al.Early changes in liver perfusion caused by occult metastasis in rats: detection with quantitative CT[J].Radiology,2001,218(2):556-561.
  • 9[9]Blomley M,Coulden R,Bufkin C,et al.Contrast bolus dynamic computed tomogrphy for the measurement of solid organ perfusion[J].Invest Radiol,1993,28(suppl 5):72-77.
  • 10[10]Bader TR,Herneth AM,Blaicher W,et al.Hepatic perfusion after liver transplantation.noninvasive measurement with dynamic singlesection CT[J].Radiology,1998,209(1):129-134.

共引文献21

同被引文献8

  • 1连海英,张雪林.磁共振灌注成像在肝硬化的临床应用[J].国外医学(临床放射学分册),2006,29(1):36-39. 被引量:9
  • 2Keogan MT, Edelman RR. Technologic advances in abdominal MR imaging. Radiology, 2001, 220:310 - 320.
  • 3Pandharipande PV, Krinsky GA, Rusinek H, et al. Perfusion imaging of the liver: current challenges and future goals. Radiology, 2005, 234: 661 - 673.
  • 4Mateme R, Smith AM, Peeters F, et al. Assessment of hepatic perfusion parameters with dynamic MRI. Magn Reson Med, 2002, 47 : 135 - 142.
  • 5Scharf J, Zapletal C, Hess T, et al. Assessment of hepatic perfusion in pigs by pharmacokinetic analysis of dynamic MR images. J Magn Reson Imaging. 1999 Apr;9:568 - 72.
  • 6Fujita T, Ito K, Honjo K, et al. Hepatic parenchymal enhancement in the cirrhotic liver: evaluation by triple-phase dynamic MRI. Abdom Imaging, 2002,27 : 29 - 33.
  • 7Ichikawa T, Arbab AS, Araki T, et al. Perfusion MR imaging with a superparamagnetic iron oxide using T2 - weighted and susceptibility - sensitive echoplanar sequences: evaluation of tumor vascularity in hepatocellular carcinoma. A.IR, 1999,173 : 207 - 213.
  • 8Annet L, Matene R, Danse E, et al. Hepatic flow parameters measured with MR imaging and Doppler US: correlations with degree of cirrhosis and portal hypertension. Radiology, 2003 Nov ;229:409 - 414.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部