摘要 以电动机转差率、电流、电压、电磁转矩的关系为理论基础,对盘车电动机的启动过程进行了分析,指出了盘车电动机投运时保险熔断的根本原因,并针对分析结果,提出了采用降压启动或变频启动的解决方法。 Based on a detailed analysis of the inter-relationship in the current, voltage, electromagentic torque and ratio of the difference between the speed of rotor and the speed of rotary magnetic field to the later in the motor, it is showed that the root cause which leads to the protection fuses~ failure of the motor in the starting stage, which drives the turbine-generator set to rotate at low speed before its startup. Two solutions to avoid the situation are proposed, too.
作者 陈吉胜
出处 《核科学与工程》 CSCD 北大核心 2005年第3期239-246,共8页 Nuclear Science and Engineering
关键词 大惯量 角加速度 静摩擦转矩 滑动摩擦转矩 big inertia rotary acceleration static friction torque sliding friction torque