摘要
针对天荒坪电厂抽水蓄能机组在检修中发现的设备腐蚀、结垢问题,经过对抽取的水样进行试验和检测,以数据分析了腐蚀和结垢的原因,并提出了更换原碳钢管、解决水质不稳定问题等改进建议。
To solve the problems of corrosion and scaling of the pumped-storage unit equipment in Tianhuangping Puwer Plant, tests and inspeetiun were carried out. The causes of corrusiou and scaling of units are analyzed, and improvement suggestions are put forward.
出处
《华东电力》
北大核心
2005年第10期50-52,共3页
East China Electric Power
关键词
抽水蓄能
腐蚀
结垢
pumped-storage
corrosion
scaling