就断路器的安装角度对热动-电磁式和全电磁式脱扣器性能的影响,断路器进出线反接对断路器分断能力的影响,及安装断路器应注意的隔离距离问题进行了讨论.
The effects of the performance of thermomagnetic and magnetic only releases under different installing angle, as well as the breaking capacity under reverse wiring, are discussed. The isolating distance of circuit breaker is analysed.
出处
《低压电器》
北大核心
1996年第1期29-31,共3页
Low Voltage Apparatus
关键词
低压断路器
安装
断路器
low voltage circuit breaker, installation, wiring