期刊文献+

300MW锅炉高温再热器超温问题的试验及分析 被引量:1

Experiment and Investigation of Overheating Problem of 300MW Boiler's HT Reheater
下载PDF
导出
摘要 针对湛江发电厂Ⅰ期工程300MW锅炉长期存在高温再热器管局部超温、再热器出口两侧汽温偏差大等问题。通过高温再热器的进、出口的冷态流场试验及进口温度分布的测试,分析了再热器管产生超温和气温偏差的原因,并结合再热器管的布置进行了说明。 The No.1 300MW boiler in Zhanjiang Power Plant has had the problems of local overheating of high temperature reheater and large steam temperature deviation at the exit of reheaters for a long time. According to the cold test of flow field at the high temperature reheaters' entrance and exit and the hot test of temperature field at it's entrance, the cause of reheater's overheating and steam temperature deviation is analyzed and an explanation associating with the structure of reheater's tubes is made.
出处 《电站系统工程》 北大核心 2005年第6期39-41,共3页 Power System Engineering
关键词 再热器 超温 锅炉 烟温偏差 reheater overheating boiler flue-gas temperature deviation
  • 相关文献

参考文献2

共引文献2

同被引文献3

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部