摘要
进行了城市污水厂二级生物处理出水氯消毒影响因素研究,结果表明:对次氯酸钠,二氧化氯消毒效果影响最大的是pH,其次是有机氮,COD,氨氮的影响相对较小。运用Selleck-Collins公式对数据进行分析。
Factors that influence disinfection of effluent of secondary hip-treatment from municipal wastewater treatment plant by chlorine were studied, the experimental results showed that: pH has the most important effect on disinfection with sodium hypochlorite and chlorine dioxide, the effects decreased gradually with organic nitrogen,COD and ammoniac nitrogen. Analysis of data by Selleck-Collins formula was done.
出处
《环境保护科学》
CAS
2005年第5期1-4,共4页
Environmental Protection Science