摘要
本文报道了C5烃中双环戊二烯过氧化物(PDCPD)快速准确的分析方法。在HOC2H4OCH3-H2O介质中,PDCPD与KI反应生成I3-,而I3-与PDCPD的量成正比,在λmax=352nm处可进行PDCPD的光度测定,测定下限为3.2×10-5mol/L,SD=0.34(10-5mol/L),RSD=1.40%。
A rapid and accurate spectrophotometric determination of perbxydicyclopentadiene (PDCPD) in C5 hydrocarbons was reported. PDCPD reacts with KI in HOC2H4OCH3-H2O medium, giving out I3-. The quantity of this I3- is proportional to the concentration of PD CPD (λmax=352 nm). The determination limit 3. 2 × 10-5 mol/L, standard deviation 0. 34 × 10-5 mol/L and relative standard deviation 1. 40% are obtained.
出处
《分析化学》
SCIE
EI
CAS
CSCD
北大核心
1996年第3期356-359,共4页
Chinese Journal of Analytical Chemistry