摘要
分析了合成氨装置脱碳系统碱液冷却器严重结垢的原因,从改变结构形式、增加保护设施和改善操作方式等方面提出了改进方案和防范措施。
Reason of seriously fouling of alkali solution cooler was analyzed for de-carbon system in ammonia synthesis plant, improvement scheme and preventive measures were presented from aspects of changing structure type, adding protective facility and improving operating mode etc.
出处
《化肥设计》
CAS
2005年第5期44-45,54,共3页
Chemical Fertilizer Design
关键词
碱液冷却器
结垢
改进措施
alkali solution cooler
fouling
improvement measures